Paper deep dive
Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration
Yizhou Wu, Yuheng Li, Xiaofeng Yang, Chih-Wei Chang
Intelligence
Status: succeeded | Model: Gemma-4-26B-A4B | Prompt: intel-v1 | Confidence: 93%
Last extracted: 8/4/2026, 5:08:48 AM
Summary
The paper proposes a digital-twin framework for anticipatory head-and-neck adaptive proton therapy using a pretrained foundation-model deformable registration network. By transferring longitudinal anatomical changes from a population database to a target patient, the method synthesizes predicted CTs (pdCTs) that better match treatment-day anatomy than static planning CTs, improving online adaptive therapy workflows without requiring repeated imaging.
Entities (10)
Relation Signals (6)
FlexiCT-2D ā isa ā Foundation Model
confidence 95% Ā· We use FlexiCT-2D [20], a Vision Transformer pretrained on 2D CT slices... foundation model
Digital Twin ā uses ā Foundation Model
confidence 95% Ā· We propose a digital-twin framework built on a pretrained foundation-model deformable registration network
Foundation Model ā implements ā Deformable Image Registration
confidence 94% Ā· We use FlexiCT-2D... a Vision Transformer pretrained on 2D CT slices... Registration is two-stage
Digital Twin ā generates ā Predicted CT (pdCT)
confidence 93% Ā· synthesized predicted CTs (pdCTs) with propagated contours
Predicted CT (pdCT) ā improves ā Head-and-neck proton therapy
confidence 90% Ā· enabling personalized online adaptive proton therapy without repeated imaging
Head-and-neck proton therapy ā targets ā Organs at Risk (OARs)
confidence 88% Ā· leading to target underdosing or organ-at-risk overdosing
Cypher Suggestions (0)
No Cypher suggestions yet.
Abstract
Abstract:Head-and-neck (HN) proton therapy is highly sensitive to anatomical change over a 4-to-6-week course, as tumor shrinkage, weight loss, and setup variation can misposition the Bragg peak near critical organs such as the parotids, oral cavity, brainstem, and spinal cord, leading to target underdosing or organ-at-risk overdosing. Online adaptive proton therapy replans on the anatomy of the day, yet standard workflows rely on offline replanning that requires repeated CT acquisition and roughly a week of preparation, adding burden, cost, and delay. We investigate whether a patient's treatment-day anatomy can be predicted before image acquisition by transferring longitudinal change from a population database. We propose a digital-twin framework built on a pretrained foundation-model deformable registration network used without patient-specific training. A first registration aligns a prior patient's planning CT to the target and carries the prior's during-treatment quality assurance CT (QACT) into the target frame; a second registration estimates the prior's planning-to-QACT change, which is then applied to the target's own planning CT to synthesize predicted CTs (pdCTs) with propagated contours. Using 88 HN patients, each with a planning CT and three QACTs, we show that pdCTs better match treatment-day anatomy than the static planning CT. Compared with the planning CT alone, normalized cross-correlation improves by 22.8%, Dice for organs-at-risk by 20.2%, and CT-number error decreases by 23.4%. Gains are largest for patients with major anatomical change and negligible when anatomy is stable. This cross-patient motion transfer leverages the digital-twin concept to anticipate treatment-day anatomy, enabling personalized online adaptive proton therapy without repeated imaging.
Tags
Links
- Source: https://arxiv.org/abs/2608.00831v1
- Canonical: https://arxiv.org/abs/2608.00831v1
Trouble viewing inline? Open PDF directly ā
Full Text
27,612 characters extracted from source content.
Expand or collapse full text
Anticipatory Digital Twins for Online Head-and-Neck Adaptive Proton Therapy via Foundation-Model Registration Yizhou Wu 1 , Yuheng Li 1 , Xiaofeng Yang 2* , Chih-Wei Chang 1* 1 Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA 30308, USA 2 Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL 60637, USA xfyang@uchicago.edu (XY); chih-wei.chang@emory.edu (C) Abstract. Head-and-neck (HN) proton therapy is highly sensitive to anatomical change over a 4-to-6-week course, as tumor shrinkage, weight loss, and setup variation can misposition the Bragg peak near critical organs such as the parotids, oral cavity, brainstem, and spinal cord, leading to target underdosing or organ- at-risk overdosing. Online adaptive proton therapy replans on the anatomy of the day, yet standard workflows rely on offline replanning that requires repeated CT acquisition and roughly a week of preparation, adding burden, cost, and delay. We investigate whether a patientās treatment-day anatomy can be predicted be- fore image acquisition by transferring longitudinal change from a population da- tabase. We propose a digital-twin framework built on a pretrained foundation- model deformable registration network used without patient-specific training. A first registration aligns a prior patientās planning CT to the target and carries the priorās during-treatment quality assurance CT (QACT) into the target frame; a second registration estimates the priorās planning-to-QACT change, which is then applied to the targetās own planning CT to synthesize predicted CTs (pdCTs) with propagated contours. Using 88 HN patients, each with a planning CT and three QACTs, we show that pdCTs better match treatment-day anatomy than the static planning CT. Compared with the planning CT alone, normalized cross-cor- relation improves by 22.8%, Dice for organs-at-risk by 20.2%, and CT-number error decreases by 23.4%. Gains are largest for patients with major anatomical change and negligible when anatomy is stable. This cross-patient motion transfer leverages the digital-twin concept to anticipate treatment-day anatomy, enabling personalized online adaptive proton therapy without repeated imaging. Keywords: Digital twins, online adaptive proton therapy, head and neck can- cer, foundation model, deformable image registration. 1 Introduction Proton radiotherapy for head-and-neck (HN) cancer is typically delivered in 30-35 frac- tions over six to seven weeks, during which patient anatomy can change substantially: 2 Anonymized Author et al. primary tumors and nodal masses regress, patients lose weight, and the parotid glands shrink and migrate medially [1]. These changes degrade the planned dose distribution, increasing dose to organs at risk (OARs) and risking target underdosage [2]. Adaptive proton therapy (APT) addresses this by replanning on the treatment-day anatomy [3], but it requires acquiring a new CT scan and re-delineating targets and OARs before a new plan can be generated. The combined burden of image acquisition, contouring, and patient scheduling means APT is usually performed offline, along a five-to-seven-day replanning care path. Such a reactive workflow can compromise treatment quality, be- cause the anatomical drift it responds to has already occurred. Online APT instead aims to capture same-day variation while the patient remains on the couch; however, the complexity of robust proton optimization means more than an hour is typically needed before a new plan is ready for physician and physicist review. A digital-twin (DT) strategy, which simulates the patient in silico to support treatment decisions, offers a path to fast online APT that proactively anticipates treatment-day anatomy and preserves personalized plan quality [4-11]. Following the consensus fram- ing of medical digital twins [12, 13], such a model couples a virtual patient representa- tion to its physical counterpart, synchronizes with treatment-day data, and feeds pre- dictions back to inform adaptation. If a patientās potential treatment-day anatomy can be predicted before imaging, multiple predicted CT (pdCT) image sets spanning plau- sible anatomical variations can be synthesized offline, and a precomputed DT-based plan library can be constructed to enable fast online APT through optimal plan selection on the treatment-day anatomy. The central difficulty is that anatomical change is pa- tient-specific and partly stochastic, so the generated pdCT sets must be sufficiently di- verse to cover this uncertainty. Existing planning-image tools do not predict future anatomy. Deformable image regis- tration (DIR) propagates contours and accumulates dose, but it operates between al- ready-acquired images and cannot synthesize anatomy that does not yet exist [14, 15]. Synthetic-CT methods (e.g., from CBCT or MRI) reconstruct treatment-day anatomy from a same-day scan, again requiring an acquisition [16, 17]. Statistical and biome- chanical models can extrapolate change but typically depend on population training data or patient-specific tumor models [18]. Atlas-based approaches transfer information across patients, but predominantly for segmentation rather than for synthesizing a fu- ture CT [19]. In this work, we propose a DT framework that leverages a foundation model to synthe- size pdCT with propagated contours for fast HN online APT, via a two-step DIR scheme producing two deformation vector fields (DVF 1 and DVF 2 ). The framework makes three contributions. (i) We synthesize multiple pdCT by cross-patient transfer of anatomical change: a prior patientās planning-to-QACT change is aligned to a new tar- get via a cross-patient registration (DVF 1 ) and then re-estimated and applied on the targetās own planning CT (DVF 2 ), so the prediction reflects the prior patientās change while remaining anchored to the targetās own anatomy. (i) We integrate a pretrained foundation model into the DT framework, reused without patient-specific training, to provide robust DIR and consistent propagation of target and OAR contours. (i) We show that a composite score combining intensity, structural, and deformation-regularity metrics can evaluate pdCT quality and feasibility for downstream online HN APT Anticipatory Digital Twins via Foundation Registration for HN Proton Therapy 3 across 1,740 (DVF 1 ) and 5,220 (DVF 2 ) cross-patient pairings, and that improvements over a no-adaptation baseline are largest precisely for the patients whose anatomy changed most. 2 Materials and Methods Overview. Fig. 1 summarizes the pipeline. The target patient has a planning CT I t (the TPCT, with planning contours S t ); its three during-treatment QA CTs Q t (1) , Q t (2) , Q t (3) capture anatomy on treatment days and serve as ground truth for evaluation only. A prior-patient library provides previously treated patients, each with a planning CT I p and three QA CTs Q p (k) , whose planning-to-QACT differences encode that prior pa- tientās anatomical change during treatment. We rank prior patients by image similarity to the target (Sec. 2.1) and then transfer the selected prior patientās planning-to-QACT change onto the target through two deformable registrations (Sec. 2.3), synthesizing predicted CTs Ć t (k) (pdCTs) with propagated contours Å t (k) . The pdCT is expected to match the targetās treatment-day QACT more closely than the static planning CT does, anticipating anatomical change before any treatment-day image is acquired. Through- out, R(F, M) denotes a single pretrained 2D deformable registration model, reused with- out patient-specific fine-tuning, that returns the DVF Ļ aligning moving image M to fixed image F; Ļ ā X denotes warping image (or contour set) X by Ļ. Fig. 1. Proposed digital-twin framework for predicted-CT generation. A prior patient's planning CT is aligned to the target (Ļā, DVFā), bringing the prior QACTs into the target frame; the prior's planning-to-QACT change is estimated per QACT (Ļā (k) , DVFā) and applied to the target plan- ning CT to synthesize three pdCTs, with contours propagated by the same fields. 2.1 Prior patient selection and atlas ranking All scans are rigidly aligned to the targetās planning grid. For each candidate prior pa- tient we compute a composite image-similarity score between I t and I p that combines, Digital-Twin Framework for Predicted-CT (pdCT) Generation forOnline HN APT pdCT 4 Anonymized Author et al. with equal weight, normalized cross-correlation (NCC) for intensity agreement, learned perceptual image-patch similarity (LPIPS) for deep-feature structural similarity, and mutual information (MI) for statistical dependence. Equal weighting avoids over-fa- voring any single criterion absent a priori evidence of metric dominance. Candidate priors are ranked by this composite score and the top-K are retained as motion sources; the most similar prior provides the primary prediction. 2.2 Pretrained registration foundation model All registrations R(Ā·,Ā·) are computed with a single, frozen, patient-agnostic foundation model. We use FlexiCT-2D [20], a Vision Transformer pretrained on 2D CT slices by agglomerative continual self-supervised pretraining (patch size 8, embedding dimen- sion 864, 16 blocks, 12 heads); the public checkpoint is reused without fine-tuning. Each volume is encoded slice-wise on an 80Ć70 patch-token grid; tokens from the last four layers form a 3456-dimensional per-token descriptor, projected to 24 channels by low-rank PCA. Registration is two-stage: a coupled-convex search at 6Ć downsampling gives a smooth coarse field (±4-grid-point window, inverse-consistency refinement), from which a dense voxel-displacement field Ļ ā ā HĆWĆDĆ3 is refined for 500 Adam iterations (lr = 6) on the features (downsampled 2Ć), with H, W, D the image height, width, and depth and the last dimension the three displacement components. The ob- jective is a sum-of-squared-differences feature loss plus a first-order diffusion penalty weighted by Ī» (Ī» = 1). The output of Ī» (Ī» = 1). The output of R is Ļ in voxel units; image and label warps use trilinear and nearest-neighbour interpolation. FlexiCT-2D was pre- trained on 266,227 public CT volumes from 56 datasets spanning multiple body regions including HN CT sets [21, 22], and is applied frozen, with no fine-tuning on our cohort. 2.3 Cross-patient longitudinal motion transfer The transfer proceeds in two registration steps followed by prediction. Step 1: Cross-patient alignment (Ļ 1 , DVF 1 ). A cross-patient registration aligns the prior planning CT to the target planning CT and brings all prior time points onto the target grid: Ļ 1 = R(I t , I p ), ÄØ p = Ļ 1 ā I p , Q Ģ p (k) = Ļ 1 ā Q p (k) , k = 1,2,3 (1) where ÄØ p (dTPCT) and Q Ģ p (k) (dQACTs) are the prior patientās planning and QA images expressed in the targetās anatomy. Step 2: Longitudinal change (Ļ 2 (k) , DVF 2 ). On the target grid, a longitudinal registra- tion estimates the prior patientās planning-to-QACT deformation for each of its three QACTs, now expressed in the targetās anatomy: Ļ 2 (k) = R(Q Ģ p (k) , ÄØ p ), k = 1,2,3 (2) Step 3: Prediction. Each longitudinal change is applied to the target patientās own planning CT to synthesize three pdCTs, with the planning contours propagated by the same fields (nearest-neighbour interpolation): Ć t (k) = Ļ 2 (k) ā I t (pdCT), Å t (k) = Ļ 2 (k) ā S t , k = 1,2,3 (3) Anticipatory Digital Twins via Foundation Registration for HN Proton Therapy 5 The two steps are complementary: Ļ 1 removes inter-patient anatomical differences so that Ļ 2 (k) captures change rather than identity, while applying Ļ 2 (k) to I t keeps each pre- diction anchored to the target patientās own anatomy. Because the foundation model is reused without any patient-specific optimization, the pipeline requires no per-patient training. With one Ļ 1 and three Ļ 2 (k) per prior patient, the framework yields three pdCT predictions per priorātarget pairing. 2.4 Dataset and evaluation Dataset. We use a retrospective cohort of 88 HN patients, each with a planning CT (TPCT) and three same-geometry QA CTs (QACT) acquired during treatment; the TPCT is the reference and the QACTs are the treatment-day ground truth. Scans are rigidly aligned to the planning grid (0.977Ć0.977 m in-plane, 1.5 m slices, 512Ć512 matrix), with up to 45 OAR segmentations per scan (brainstem, cord, parotids, larynx, constrictors, and others). The dataset source is masked for anonymization, with an eth- ics statement to follow after de-anonymization. This institutional cohort is disjoint from the public data used to pretrain the registration model (Sec. 2.2), so there is no trainā test leakage. Evaluation protocol. We evaluate 20 patients as targets, which result in 5,220 pdCTs with 1,740 (DVF 1 ) and 5,220 (DVF 2 ); for each target, prior patients are drawn from the remaining cohort and the targetās own QACTs are held out as ground truth. The base- line is no adaptation, which uses the planning CT directly on the treatment day and is the current default when no replan is acquired. It is evaluated by comparing I t against each Q t (k) . The proposed method is evaluated by comparing each pdCT Ć t (k) against the corresponding QACT. All metrics are computed within a body mask. We report com- plementary aspects of agreement: NCC and SSIM (intensity and structural agreement) and MAE in HU (intensity error); mean Dice (OAR volumetric overlap), mean HD95 and ASSD in m (OAR boundary distance), averaged over structures common to the prediction and QACT. Composite quality score. To summarize overall performance with a single number, we map each of six metrics to a composite score with [0,1] scale on which higher is better and average them with equal weights. NCC, SSIM, and Dice already lie in [0,1] and are used directly; the three error metrics are inverse-normalized and clipped: Composite = ā (NCC+SSIM+Dice+clip(1āMAE/M)+clip(1āHD95/Ī“)+clip(1āASSD/Ī“)) (4) where M = 2000 HU is the CT intensity range used to normalize MAE, Ī“ = 50 m caps the boundary distances, and clip(x) = min(max(x,0),1). A higher Composite indicates better overall agreement with the treatment-day QACT. Implementation. Registration hyper-parameters are fixed across all cases (Sec. 2.2). Prior-patient sessions are resampled onto the target grid (linear for intensities, nearest- neighbour for labels) prior to Ļ 1 . Experiments run on NVIDIA A100 GPUs at roughly 22 min per prediction. Ablation. To test whether the predicted change must be applied to the targetās own anatomy, we compare the full method (pdCT) against an ablated variant that removes the longitudinal-change step Ļ 2 (k) (pdCT no Ļ 2 ): the Ļ 1 -aligned prior QACT Q Ģ p (k) is used 6 Anonymized Author et al. directly as the prediction, substituting the prior patientās anatomy for the targetās (Sec. 3). 3 Results and Discussion 3.1 Results Quantitative agreement. For each target we evaluate the most challenging treatment- day anatomy, the QACT with the largest change from the planning CT, where no ad- aptation fails worst and prediction matters most. As Table 1 shows, the predicted CT improves over the no-adaptation baseline on every metric: intensity and structural agreement (NCC, SSIM), mean absolute error (MAE), and OAR overlap and boundary accuracy (Dice, HD95, ASSD), raising the aggregate Composite score from 0.77 to 0.82. Per-patient relative gains exceed 20% for both NCC and Dice. Table 1. Agreement with the treatment-day QACT (largest-change QACT per target), for no adaptation (TPCT) vs. the predicted CT (pdCT). Values are mean ± SD over 20 targets; Improved is the per-patient relative gain. NCC SSIM Dice MAE (HU) HD95 (m) ASSD (m) Composite Score TPCT 0.61±0.12 0.83±0.04 0.49±0.13 110.4±24.3 8.9±2.9 3.7±1.4 0.77±0.06 pdC T 0.75±0.10 0.86±0.03 0.59±0.11 89.5±16.8 7.9±2.8 3.1±1.3 0.82±0.05 Gain 22.8% 2.8% 20.2% 23.4% 10.6% 17.7% 6.6% HD = Hausdorff Distance; ASSD = Average Symmetric Surface Distance Image comparisons. Fig. 2 shows, for a representative case, the planning CT (TPCT), the predicted CT (pdCT), and the treatment-day QACT together with absolute-error maps against the QACT: pdCT visibly reduces residual error in regions of anatomical change while preserving image realism. Fig. 3 overlays propagated OAR contours on the QACT for the TPCT and pdCT conditions, showing improved overlap (per-struc- ture Dice annotated). Fig. 2. CT quality and error for a representative target patient, on a coronal slice. Col- umns: planning CT (TPCT), predicted CT (pdCT), treatment-day QACT, and absolute- TPCTpCTQACT|TPCT āQACT| |pCTāQACT| Anticipatory Digital Twins via Foundation Registration for HN Proton Therapy 7 error maps |TPCT ā QACT | and |pdCT ā QACT | on a shared scale. pdCT reduces residual error in regions of anatomical change while preserving image realism. Fig. 3. Propagated OAR contours on the treatment-day QACT for a representative target. Rows: TPCT (no adaptation) vs pdCT; columns: brainstem, spinal cord, pharyngeal constrictor. Or- ange/green = overlap with the QACT for TPCT / pdCT; blue outline = QACT; per-panel Dice annotated. 3.2 Ablations Removing the longitudinal-change step. We compare the full method (pdCT) against an ablated variant, pdCT no Ļā, that skips Ļā and instead deformably aligns the prior patientās QACT to the target via Ļā and uses it directly, transferring the prior patientās anatomy rather than its longitudinal change (Fig. 4). This variant decreases intensity correlation. It also degrades every structural metric below the full method results since the organ shapes and positions belong to the prior patientās anatomy. Applying the change to the target's own anatomy (full pdCT) is best on every metric, confirming the core design choice: the value comes from transferring the change, not the anatomy. Fig. 4. Ablation: full method (pdCT) vs. the variant without the longitudinal-change step (pdCT no Ļā), mean ± SD over 20 patients. Using the Ļā-aligned prior QACT di- rectly raises NCC but degrades all structural metrics, while pdCT is best on every met- ric. 8 Anonymized Author et al. 3.3 Discussion The central finding is that a prior patientās planning-to-QACT change, once re-ex- pressed on the target through a single cross-patient registration, predicts the targetās own treatment-day anatomy more faithfully than the static planning CT does. This suc- ceeds because anatomical change in HN radiotherapy is largely canonical across pa- tients: tumor and nodal regression, weight-loss-driven neck thinning, and medial pa- rotid migration recur in similar directions and locations, so a longitudinal deformation learned on one patient is informative for another. The two-step design is what makes this usable. The cross-patient field Ļ 1 first removes inter-patient anatomical differences so that Ļ 2 (k) encodes change rather than identity, and applying Ļ 2 (k) to the targetās own planning CT keeps the prediction anchored to the targetās anatomy. The low folding fraction of Ļ 2 (k) confirms that the predicted change is a physically plausible warp rather than a registration artifact. The ablation isolates the source of the gain. Using the Ļ 1 -aligned prior QACT directly (pdCT no Ļ 2 ) raises intensity correlation, because a globally aligned prior patient re- sembles the target in bulk, yet it degrades every structural metric below the no-adapta- tion baseline, because the borrowed organ shapes and positions belong to the prior pa- tient. Only by transferring the change to the targetās own anatomy does the method improve both intensity and structural agreement. The value comes from transferring the change, not the anatomy. This also explains why gains are largest precisely for the pa- tients whose anatomy changed most and negligible when anatomy is stable, and it mo- tivates our evaluation on the largest-change QACT, the case that most needs adaptation. The dominant remaining bottleneck is prior-patient selection. Our primary results rank candidate priors against the held-out QACT, an oracle unavailable at instantiation time. The composite image-similarity score (NCC, LPIPS, MI) is a step toward a deployable selector, but closing the gap to the oracle ranking will likely require a learned, ground- truth-free scorer that predicts which priors carry transferable change for a given target. Clinically, the framework reframes adaptation from reactive to proactive: because pdCTs and their contours are synthesized before any treatment-day image is acquired, a precomputed plan library can be selected on the day rather than triggering a multi- day replanning path after drift has occurred. Two limitations bound the study: the eval- uation is in the image domain, so dose-domain validation of proton plan quality on the predicted anatomy is needed before clinical use; and the cohort is single-institution and retrospective, so prospective, multi-site validation remains essential. 4 Conclusions This work positions cross-patient longitudinal motion transfer as a viable building block for digital twins in adaptive radiotherapy. Using a single pretrained foundation registration model without any patient-specific training, we synthesize predicted CTs and propagated contours that better match the target's treatment-day anatomy than the static planning CT on every evaluated metric, with physically plausible deformations. The gains are largest for the patients whose anatomy changed most, and an ablation confirms that the benefit comes from transferring the prior patient's longitudinal change Anticipatory Digital Twins via Foundation Registration for HN Proton Therapy 9 to the target's own anatomy rather than borrowing the prior patient's anatomy. Because the prediction is produced before any treatment-day image is acquired, the framework offers a route to shift HN online adaptive proton therapy from reactive to proactive. Learning a ground-truth-free prior-patient selector, together with dose-domain evalua- tion and prospective validation, is the principal direction for future work. Acknowledgments. This research is supported in part by the National Institutes of Health under Award Number R01DE033512 and R01CA272991. Disclosure of Interests. The authors have no competing interests to declare that are relevant to the content of this article. References 1. Lalonde A, BobiÄ M, Winey B, Verburg J, Sharp GC, Paganetti H. Anatomic changes in head and neck intensity-modulated proton therapy: Comparison between robust optimization and online adaptation. Radiother Oncol. 2021;159:39ā47. doi: 10.1016/j.radonc.2021.03.008. 2. Chang CW, Bohannon D, Tian Z, Wang Y, McDonald MW, Yu DS, et al. A retrospective study on the investigation of potential dosimetric benefits of online adaptive proton therapy for head and neck cancer. J Appl Clin Med Phys. 2024;25(5):e14308. doi: 10.1002/acm2.14308. 3. Paganetti H, Botas P, Sharp GC, Winey B. Adaptive proton therapy. Phys Med Biol. 2021;66(22). doi: 10.1088/1361-6560/ac344f. 4. Katsoulakis E, Wang Q, Wu H, Shahriyari L, Fletcher R, Liu J, et al. Digital twins for health: a scoping review. npj Digital Medicine. 2024;7(1):77. doi: 10.1038/s41746-024-01073-0. 5. Chang CW, Tian Z, Qiu RLJ, Scott Mcginnis H, Bohannon D, Patel P, et al. Exploration of an adaptive proton therapy strategy using CBCT with the concept of digital twins. Phys Med Biol. 2025;70(2). doi: 10.1088/1361-6560/ada684. 6. Mekki YM, Luijten G, Hagert E, Belkhair S, Varghese C, Qadir J, et al. Digital twins for the era of personalized surgery. npj Digital Medicine. 2025;8(1):283. doi: 10.1038/s41746-025- 01575-5. 7. Pammi M, Shah PS, Yang LK, Hagan J, Aghaeepour N, Neu J. Digital twins, synthetic patient data, and in-silico trials: can they empower paediatric clinical trials? The Lancet Digital Health. 2025;7(5). doi: 10.1016/j.landig.2025.01.007. 8. Zhao F, Wu Y, Hu M, Chang C-W, Liu R, Qiu R, et al. Current progress of digital twin construction using medical imaging. Journal of Applied Clinical Medical Physics. 2025;26(9):e70226. doi: https://doi.org/10.1002/acm2.70226. 9. Chang C-W, Safari M, Akkineni S, Hu M, Shah KD, Patel P, et al. A Deep Learning-Enabled Digital Twin Framework for Fast Online Adaptive Proton Therapy: A Validation Study in A Prostate SBRT Clinical Application. In: Yuankai H, Mingchen G, Chang-Fu K, Yueming J, Ruining D, editors. Proceedings of The 9th International Conference on Medical Imaging with Deep Learning. Proceedings of Machine Learning Research: PMLR; 2026. p. 1193ā216. 10. Chang C-W, Safari M, Akkineni SSL, Hu M, Shah K, Gao Y, et al. A digital twin framework for adaptive treatment planning in radiotherapy. Physics in Medicine & Biology. 2026. 10 Anonymized Author et al. 11. Sud A, Huang J, Hart GR, Saxena K, Kim J, Tressel L, et al. A Patient-Specific Digital Twin for Adaptive Radiotherapy of Non-Small Cell Lung Cancer. arXiv preprint arXiv:260218496. 2026. 12. National Academies of Sciences E, Medicine, National Academy of E, Division on E, Life S, Division on E, et al. The National Academies Collection: Reports funded by National Institutes of Health. Foundational Research Gaps and Future Directions for Digital Twins. Washington (DC): National Academies Press (US) Copyright 2024 by the National Academy of Sciences. All rights reserved.; 2024. 13. SadĆ©e C, Testa S, Barba T, Hartmann K, Schuessler M, Thieme A, et al. Medical digital twins: enabling precision medicine and medical artificial intelligence. The Lancet Digital Health. 2025;7(7). doi: 10.1016/j.landig.2025.02.004. 14. Nenoff L, Amstutz F, Murr M, Archibald-Heeren B, Fusella M, Hussein M, et al. Review and recommendations on deformable image registration uncertainties for radiotherapy applications. Phys Med Biol. 2023;68(24). doi: 10.1088/1361-6560/ad0d8a. 15. Sotiras A, Davatzikos C, Paragios N. Deformable medical image registration: a survey. IEEE Trans Med Imaging. 2013;32(7):1153ā90. doi: 10.1109/tmi.2013.2265603. 16. Bahloul MA, Jabeen S, Benoumhani S, Alsaleh HA, Belkhatir Z, Al-Wabil A. Advancements in synthetic CT generation from MRI: A review of techniques, and trends in radiation therapy planning. J Appl Clin Med Phys. 2024;25(11):e14499. doi: 10.1002/acm2.14499. 17. Peng J, Qiu RLJ, Wynne JF, Chang CW, Pan S, Wang T, et al. CBCT-Based synthetic CT image generation using conditional denoising diffusion probabilistic model. Med Phys. 2024;51(3):1847ā59. doi: 10.1002/mp.16704. 18. Anderson BM, Lin YM, Lin EY, Cazoulat G, Gupta S, Kyle Jones A, et al. A novel use of biomechanical model-based deformable image registration (DIR) for assessing colorectal liver metastases ablation outcomes. Med Phys. 2021;48(10):6226ā36. doi: 10.1002/mp.15147. 19. Iglesias JE, Sabuncu MR. Multi-atlas segmentation of biomedical images: A survey. Med Image Anal. 2015;24(1):205ā19. doi: 10.1016/j.media.2015.06.012. 20. Li Y, Gao Y, Dong H, Lai Y, Wang S, Safari M, et al. Universal CT Representations from Anatomy to Disease Phenotype through Agglomerative Pretraining. arXiv preprint arXiv:260521906. 2026. 21. Grossberg AJ, Mohamed ASR, Elhalawani H, Bennett WC, Smith KE, Nolan TS, et al. Imaging and clinical data archive for head and neck squamous cell carcinoma patients treated with radiotherapy. Scientific Data. 2018;5(1):180173. doi: 10.1038/sdata.2018.173. 22. Oreiller V, Andrearczyk V, Jreige M, Boughdad S, Elhalawani H, Castelli J, et al. Head and neck tumor segmentation in PET/CT: The HECKTOR challenge. Medical Image Analysis. 2022;77:102336. doi: https://doi.org/10.1016/j.media.2021.102336.