Paper deep dive
From Days to Minutes: An Autonomous AI Agent Achieves Reliable Clinical Triage in Remote Patient Monitoring
Seunghwan Kim, Tiffany H. Kung, Heena Verma, Dilan Edirisinghe, Kaveh Sedehi, Johanna Alvarez, Diane Shilling, Audra Lisa Doyle, Ajit Chary, William Borden, Ming Jack Po
Intelligence
Status: succeeded | Model: google/gemini-3.1-flash-lite-preview | Prompt: intel-v1 | Confidence: 98%
Last extracted: 3/13/2026, 12:58:04 AM
Summary
The paper introduces 'Sentinel', an autonomous AI agent utilizing the Model Context Protocol (MCP) to perform clinical triage on remote patient monitoring (RPM) data. By integrating 21 clinical tools for multi-step reasoning, Sentinel addresses the 'data flood' problem that caused previous RPM trials to fail. Evaluation against human clinicians and rule-based baselines demonstrates that Sentinel achieves superior emergency sensitivity (97.5% vs 60.0% aggregate) and actionable sensitivity, while maintaining high self-consistency and a cost-effective, scalable profile for chronic disease management.
Entities (5)
Relation Signals (3)
AnsibleHealth â developed â Sentinel
confidence 100% · We developed Sentinel, an autonomous AI agent
Sentinel â performs â Remote Patient Monitoring
confidence 100% · Sentinel triages RPM vitals with sensitivity exceeding individual clinicians.
Sentinel â uses â Model Context Protocol
confidence 100% · We developed Sentinel, an autonomous AI agent using Model Context Protocol (MCP)
Cypher Suggestions (0)
No Cypher suggestions yet.
Abstract
Abstract:Background: Remote patient monitoring (RPM) generates vast data, yet landmark trials (Tele-HF, BEAT-HF) failed because data volume overwhelmed clinical staff. While TIM-HF2 showed 24/7 physician-led monitoring reduces mortality by 30%, this model remains prohibitively expensive and unscalable. Methods: We developed Sentinel, an autonomous AI agent using Model Context Protocol (MCP) for contextual triage of RPM vitals via 21 clinical tools and multi-step reasoning. Evaluation included: (1) self-consistency (100 readings x 5 runs); (2) comparison against rule-based thresholds; and (3) validation against 6 clinicians (3 physicians, 3 NPs) using a connected matrix design. A leave-one-out (LOO) analysis compared the agent against individual clinicians; severe overtriage cases underwent independent physician adjudication. Results: Against a human majority-vote standard (N=467), the agent achieved 95.8% emergency sensitivity and 88.5% sensitivity for all actionable alerts (85.7% specificity). Four-level exact accuracy was 69.4% (quadratic-weighted kappa=0.778); 95.9% of classifications were within one severity level. In LOO analysis, the agent outperformed every clinician in emergency sensitivity (97.5% vs. 60.0% aggregate) and actionable sensitivity (90.9% vs. 69.5%). While disagreements skewed toward overtriage (22.5%), independent adjudication of severe gaps (>=2 levels) validated agent escalation in 88-94% of cases; consensus resolution validated 100%. The agent showed near-perfect self-consistency (kappa=0.850). Median cost was $0.34/triage. Conclusions: Sentinel triages RPM vitals with sensitivity exceeding individual clinicians. By automating systematic context synthesis, Sentinel addresses the core limitation of prior RPM trials, offering a scalable path toward the intensive monitoring shown to reduce mortality while maintaining a clinically defensible overtriage profile.
Tags
Links
- Source: https://arxiv.org/abs/2603.09052v1
- Canonical: https://arxiv.org/abs/2603.09052v1
Trouble viewing inline? Open PDF directly â
Full Text
94,939 characters extracted from source content.
Expand or collapse full text
From Days to Minutes: An Autonomous AI Agent Achieves Reliable Clinical Triage in Remote Patient Monitoring Authors: Seunghwan Kim, PhD 1 , Tiffany H. Kung, MD 1,2 , Heena Verma 1 , Dilan Edirisinghe 1 , Kaveh Sedehi, MBA 1 , Johanna Alvarez, MSN, FNP-BC 1 , Diane Shilling, DNP, FNP-C 1 , Audra Lisa Doyle, MSN, FNP-BC 1 , Ajit Chary, MD 1 , William Borden, MD 1,3 , Ming Jack Po, MD, PhD 1 1 AnsibleHealth Inc., San Francisco, CA, USA 2 Department of Anesthesiology, Perioperative and Pain Medicine, Stanford School of Medicine, Stanford, CA 3 Department of Medicine, Division of Cardiology, George Washington University, Washington, DC Correspondence: nigel.kim@ansiblehealth.com Abstract Background. Remote patient monitoring (RPM) generates vast quantities of vital sign data, yet landmark heart failure trialsâincluding Tele-HF, BEAT-HF, and TIM-HF1âfailed to improve outcomes because data floods overwhelmed clinical staff without intelligent filtering or contextual interpretation. TIM-HF2 proved that structured, responsive monitoring with 24/7 physician staffing reduces mortality by 30%, but this model is prohibitively expensive and unscalable. Methods. We developed Sentinel, an autonomous AI agent using Model Context Protocol (MCP) to perform contextual clinical triage of RPM vital signs. The system equips a large language model with 21 structured clinical tools for comprehensive patient context retrieval, enabling multi-step clinical reasoning for each reading. We evaluated Sentinel through three studies: (1) agent self-consistency via inter-rater reliability (100 readings Ă 5 runs, Fleissâ Îș); (2) comparison against rule-based threshold baselines on 500 readings from 340 patients; and (3) validation against 6 human clinicians (3 physicians, 3 nurse practitioners) using a connected matrix design (3 reviewers per sample). A leave-one-out (LOO) analysis compared the agent against each individual clinician, and all agent overtriage cases underwent independent clinical adjudication. Results. The agent achieved 95.8% sensitivity for emergency classifications (23/24) and 88.5% sensitivity for all actionable alerts (emergency + urgent; 92/104), with 85.7% specificity (311/363) against the human majority-vote reference standard (N=467, ties excluded). Four-level exact accuracy was 69.4% (324/467) with a quadratic-weighted kappa of 0.778 (95% CI: 0.728â0.819), and 95.9% of classifications fell within one severity level. In leave-one-out analysis, the agent outperformed every individual clinician in both emergency sensitivity (97.5% vs. clinician aggregate 60.0%) and actionable sensitivity (90.9% vs. 69.5%). Agent-human disagreements skewed toward overtriage (22.5%) rather than undertriage (8.1%); independent physician adjudication of the 17 most severe overtriage cases (agentâ majority gap â„2 levels) found that both reviewers independently validated the agentâs escalation in 88â 94% of cases, with true overtriage confirmed in only 6â12%; subsequent consensus resolution between the two reviewers validated all agentâs escalations (100% non-overtriage). The agent demonstrated almost perfect self-consistency (Fleissâ Îș = 0.850 [95% CI: 0.786â0.909], 83% perfect 5/5 agreement). The system operated at a median cost of $0.34 per triage in 94.5 seconds. Conclusions. These findings demonstrate that autonomous AI agents can perform reliable, contextual clinical triage of RPM vital signs with sensitivity to clinical deterioration that, in this retrospective evaluation under our study design, exceeded that of individual human clinicians reviewing pre-assembled context summaries. Sentinel substantially outperformed rule-based thresholds, achieved agreement with clinician panels comparable to inter-clinician agreement, andâin head-to-head leave-one-out comparisonâdetected emergencies more reliably than any individual clinician while maintaining a clinically defensible overtriage profile. The agentâs ability to systematically retrieve and synthesize full patient context for every reading addresses the core limitation that undermined prior RPM trials. At $0.34 per triage, this approach offers a scalable path toward the intensive, contextualized monitoring model that TIM-HF2 showed reduces mortality. Keywords: remote patient monitoring; artificial intelligence; clinical decision support; agentic AI; Model Context Protocol; inter-rater reliability; alert fatigue; chronic disease management; leave-one-out analysis 1. Introduction Noncommunicable chronic diseases account for 74% of global deaths. 1 In the U.S., 90% of the nationâs $4.9 trillion annual health expenditures are for people with chronic and mental health conditions. 2,3 Remote patient monitoring (RPM)âthe collection and clinical review of patient-generated health data outside traditional care settingsâhas been widely promoted as a solution for managing chronic conditions including heart failure (HF), hypertension, and diabetes. 4 By 2025, over 70 million Americans were projected to use RPM devices. RPM adoption in the United States has surged in recent years, with over 13.5 million Medicare remote monitoring services delivered between 2019 and 2023, generating an unprecedented volume of clinical data. 5,6 Yet the central promise of RPMâthat more data enables better careâhas been undermined by a fundamental paradox: the data floods that RPM produces overwhelm the very clinicians who must act on them. 1.1 The Failed Trials and Their Lessons Three landmark randomized controlled trials in heart failure telemonitoring illustrated this paradox with devastating clarity. Tele-HF deployed telephone-based daily monitoring for HF patients and found no significant improvement in readmission or death. 7 It also revealed the mechanism of failure: the average patient generated 35 variances of alerts requiring staff-patient contact over 6 months, yet there were no specified algorithms connecting signals with responses. Clinicians were buried in threshold-crossing alerts with no way to separate signal from noise. BEAT-HF combined telemonitoring with health coaching after HF discharge and similarly failed to reduce 180-day readmissions. 8 The investigators were remarkably candid about systemic flaws, acknowledging that âthe physiological signals of changes in daily weights and increased symptoms may not provide adequate warning of impending decompensationâ without clinical context. Weightâthe primary monitored parameterâwas a poor surrogate for cardiac filling pressures when interpreted in isolation. TIM-HF1 also failed to show benefit in the overall population, though a pre-specified subgroup analysis suggested benefit among patients without major depression who had a recent HF hospitalization. 9,10 A meta-analysis found that the lowest mortality was associated with interventions performed within one day of a vital sign change; 11 later syntheses note persistent heterogeneity in home telemonitoring systems. 12 Drawing on early neutral trials and the 2023 JACC Scientific Statement, 13 we summarize recurring architectural failure modes: â Data flood without intelligent filtering. Every threshold crossing demanded human attention regardless of clinical significance, producing classic alert fatigue. This systemic vulnerability is well-documented: only 15% were clinically relevant, 14 RPM and CDS-related alert override rates range from 37.9% to 59.6%, 15,16 threshold-based alerting at population-scale RPM produces clinically unsustainable notification volumes, 7,8 and the Joint Commission has identified alarm- related sentinel events including patient deaths. 17 â No structured response protocol. Detection of an abnormal value triggered no specified algorithm for response, creating a âbroken loopâ or inconsistency from detection to action. â Lack of contextual interpretation. Raw vital signs were assessed without medication context, comorbidity awareness, baseline personalization, or trend analysis. â Catastrophic adherence failure. Systems requiring active patient engagement suffered rapid attrition and data loss. â No population targeting. Monitoring all patients equally, regardless of risk, diluted resource allocation and statistical power. 1.2 TIM-HF2: Proof That Structured Monitoring Saves Lives TIM-HF2 systematically addressed these failure modes and succeeded. 18 By deploying a 24/7 physician- staffed telemedical center with structured response protocols, TIM-HF2 reduced all-cause mortality by 30% (HR 0.70, 95% CI 0.50â0.96; p=0.028) and unplanned hospitalization days by 20%. Extended follow-up confirmed that benefits disappeared within one year of stopping the intervention. 19 The key element was that a well-structured telemedical center providing 24/7 service was present, with empowered clinicians who could change medication regimens. 18,20 TIM-HF2 proved that responsive, contextualized, structured monitoring saves lives. But it solved the problem by deploying expensive 24/7 human infrastructure that cannot scale. 1.3 AI Agents as a Paradigm Shift We propose that effective monitoring requires not better algorithms or lower thresholds, but a fundamentally different class of system: an autonomous AI agent capable of clinical reasoning with full patient context and structured action capabilities. Such a system must be precisely calibrated between two failure modes. Undertriageâclassifying a deteriorating patient as stableârisks missed emergencies and preventable harm. But overtriage may be equally dangerous at scale: if an AI system flags 50% of readings as urgent, as simple threshold rules do, it recreates the exact data flood that overwhelmed clinicians in Tele-HF and BEAT-HF, rendering the system clinically useless regardless of its sensitivity. An effective AI triage agent must therefore demonstrate not only that it catches true emergencies, but that it does so without generating the unsustainable alert volumes that erode clinician trust and attentionâthe very alarm fatigue that prior RPM trials proved fatal to their own efficacy. Large language models (LLMs) have achieved high performance on medical QA and clinical knowledge benchmarks. 21-24 However, standalone LLMs lack structured data access for real-world clinical decision- making. The emerging paradigm of agentic AIâLLMs augmented with tool-calling capabilitiesâ addresses this limitation. Model Context Protocol (MCP) provides a standardized interface for connecting AI agents to structured data sources. 25 We present Sentinel, to our knowledge the first deployed autonomous AI agent system using MCP for clinical triage in outpatient RPM. This system directly addresses the five architectural failure modes of prior trials. Its 21 clinical tools provide the deep contextual interpretation that was previously missing, and its AI-driven reasoning acts as an intelligent filter to prevent data floods. Crucially, the agent autonomously determines which clinical data to retrieve at runtimeâdynamically selecting from patient history, medications, diagnoses, clinical notes, and prior encounters based on the specific clinical context of each readingârather than following a fixed data retrieval sequence. Its structured analytical output provides a clear, actionable signal, closing the loop from detection to response. In this study, we evaluated Sentinelâs reliability, compared its performance against rule-based baselines and human clinicians, and conducted a leave-one-out analysis comparing the agent against each individual clinician alongside independent clinical adjudication of agent overtriage cases. 2. Related Work 2.1 Commercial RPM Platforms Many RPM programs still operationalize alerts with heuristic threshold rules, while some vendors add machine learning (ML)-derived indices. 26 Several platforms have introduced varying degrees of algorithmic sophistication. Biofourmis employs ML-based physiological modeling to generate personalized health indices, demonstrating high sensitivity (94.1%) and specificity (88.9%) for detecting clinical deterioration in a single-center observational study of 34 hospitalized mild COVID-19 patients. 27 The platform, originally known for hospital-at-home and acute care solutions, has since expanded across the care continuum through its 2024 merger with CopilotIQ, creating an end-to-end platform spanning pre-surgical optimization, acute, post-acute, and chronic in-home care. 28 Health Recovery Solutions, recognized as Best-in-KLAS for RPM in 2023, offers nurse-staffed clinical triage services, which provide RN-led monitoring and escalation for RPM patients. 29,30 Masimo SafetyNet provides continuous SpO2 monitoring with configurable alert thresholds based on institutional clinical protocols, primarily relying on clinician-configured parameters rather than automatically adaptive baselines. 31 Across these platforms, a common architectural pattern persists: alerts are generated by fixed or simple statistical rules applied to individual vital sign readings, without integrating the broader clinical contextâmedications, diagnoses, hospitalization history, or temporal trendsâthat clinicians use to interpret vital signs. To the best of our knowledge, no commercial platform combines LLM-agent-powered clinical reasoning with dynamic, context-driven data retrieval for outpatient RPM triage. 2.2 LLMs and Agentic AI in Clinical Triage Although large language models (LLMs) demonstrate baseline clinical competence across medical benchmarks, 21-24 their application to patient triage yields mixed results. 32 Single-prompt models achieve physician-level accuracy in emergency department triage, 33 yet exhibit systematic over-triageâa critical calibration risk for deployment in remote patient monitoring. 32 Clinical architectures are consequently shifting toward tool-augmented workflows: COMPOSER-LLM demonstrated that pairing an LLM with a predictive model to autonomously extract clinical context during high-uncertainty cases can substantially reduce false alarms in sepsis detection. 34 Beyond single-prompt classification, autonomous clinical agents employ multi-step reasoning with structured tool access. 35 However, benchmarks confirm that agentic clinical workflows are substantially harder than static question-answering, with model accuracy often dropping. 36,37 While standardized tool- use frameworks such as MCP are emerging in healthcare, 38 clinical AI agents have remained largely confined to simulated environments. 39-41 To our knowledge, Sentinel is the first LLM agent utilizing MCP tools deployed in a clinical production environment for direct patient care. 3. Methods 3.1 Study Population The main evaluation study population comprised 340 unique patients enrolled in AnsibleHealthâs polychronic care program across 25 U.S. states, with 500 RPM device readings drawn from a representative 24-hour period from a weekday in 2026. Patient demographics were extracted from structured EHR data using the same tools available to the agent (Table 1; N=339, with 1 patient excluded due to missing data). Patients were predominantly elderly (mean age 70.3 years) and female (60.2%). The cohort was medically complex, with high rates of hypertension (45.1%), heart failure (31.9%), and diabetes mellitus (31.0%), and a median of 19 documented ICD-10 conditions per patient. Readings comprised 228 blood pressure (45.6%), 195 pulse oximetry (39.0%), and 77 body weight (15.4%) measurements. Table 1. Study Population Demographics (N=339) Characteristic Value Patients, N 339 Age, years: mean (SD) 70.3 (9.5) Age, years: median (IQR) 70 (65â77) Age, years: range 32â91 Age <50 10 (2.9%) Age 50â59 32 (9.4%) Age 60â69 116 (34.2%) Age 70â79 122 (36.0%) Age 80â89 56 (16.5%) Age â„90 3 (0.9%) Female sex 204 (60.2%) Male sex 135 (39.8%) Major Comorbidities Hypertension 153 (45.1%) Heart failure 108 (31.9%) Diabetes mellitus 105 (31.0%) Coronary artery disease 92 (27.1%) COPD 82 (24.2%) Obesity 77 (22.7%) Chronic kidney disease 73 (21.5%) Documented conditions (ICD- 10), median (range) 19 (1â399) RPM Device Readings 500 Blood pressure cuff 228 (45.6%) Pulse oximeter 195 (39.0%) Body weight scale 77 (15.4%) Note: Demographics sourced via the same tools used by the agent. One patient was excluded due to missing EHR data. 3.2 System Architecture We conducted a retrospective evaluation of Sentinel using data from AnsibleHealth, a value-based remote patient monitoring organization serving patients with chronic conditions including heart failure, hypertension, COPD, and diabetes across multiple health system partnerships. The evaluation dataset comprised vital sign readings from three home device types: blood pressure cuffs (systolic/diastolic blood pressure, pulse rate), pulse oximeters (SpO2, pulse rate), and weight scales (bodyweight). All analyses were performed offline on historical data; no patient care decisions were made during the study. 3.2.1 AI Triage Agent The triage agent used Anthropicâs claude-opus-4-6 model operating via the Claude Agent SDK in an agentic framework with structured tool access. 42 All inference parameters were set to Anthropicâs defaults (temperature = 1.0, no top_p override); no deterministic seeding was applied, as the study design intentionally leveraged stochastic variability to assess reliability. Unlike single-prompt classification systems, the agent autonomously determined which clinical data to retrieve, how many reasoning steps to take, and what contextual factors to weighâexecuting a variable-length, multi-step clinical reasoning workflow for each reading. Figure 1. Sentinel System Architecture The agent framework provided access to 21 tools organized across three services (Table 2). The patient clinical data service exposed 17 tools for retrieving structured patient data via Model Context Protocol. The ICD-10 terminology service provided diagnostic code lookup. Three native system tools (Read, Bash, Grep) enabled additional data manipulation when needed. Through these tools, the agent had access to the comprehensive electronic health record (EHR), including data aggregated from health information exchanges (HIEs) across the patientâs care network. Available data sources included patient demographics, ICD-10-coded active diagnoses, current medications with dosing, vital sign history with baseline statistics, recent encounters including hospitalizations, clinical documentation from both internal and external providers, clinician annotations on prior readings, outreach activity and call records, HIE- sourced care summaries, program enrollment status, and equipment records. Table 2. MCP Tool Inventory (N=500 trials) Tool Calls Trials Used % Trials Core tools (100% usage): getpatientdemographics 500 500 100.0% get_conditions 500 500 100.0% get_medications 500 500 100.0% get_encounters 500 500 100.0% getvitalhistory 500 500 100.0% Frequent tools (>25% usage): getrecentactivity 471 462 92.4% search_notes 356 308 61.6% getprogramstatus 309 300 60.0% getclinicalnotes 288 270 54.0% getcalldetail 450 249 49.8% gethiesummary 146 145 29.0% Occasional tools (<25% usage): getlatestvitals 129 122 24.4% Read (native) 153 58 11.6% Grep (native) 90 56 11.2% Bash (native) 92 53 10.6% getsessionhistory 5 5 100.0% getpatientequipment 3 3 100.0% icd10lookupcode 8 2 25.0% getexercisevitals_trend 1 1 100.0% getattendancesummary 1 1 100.0% get_observations 1 1 100.0% The agent selectively invoked tools based on clinical context rather than following a fixed retrieval sequence. Five core tools were called on every trial (get_patient_demographics, get_conditions, get_medications, get_encounters, get_vital_history), while additional tools were called situationally. The mean number of tool calls per trial was 10.1 (range 6â24). Higher-acuity classifications correlated with deeper investigation: emergency cases averaged 14.2 tool calls versus 8.7 for non-issue cases, a 63% increase. The agent assigned one of four severity levels: EMERGENCY (clinical outreach within 60 minutes), URGENT (within 24 hours), MONITOR (review within 14 days), and NOT AN ISSUE (no action required) (Figure 2). The system prompt included explicit escalation guardrails instructing the agent not to escalate solely on the basis of absent recent clinical contact, longstanding uncontrolled chronic disease, or high comorbidity burden without evidence of acute instability. Independent of severity, the agent classified the required follow-up into one of six action types (no action, equipment resolution, patient education, clinical review, urgent review, or care coordination) to facilitate clinical routing. Figure 2. Severity Classification Decision Guidelines. Definitions, response timeframes, clinical examples, and tie-breaker rules provided to all raters (AI agent and human clinicians). Escalation guardrails prevented classification based solely on absent clinical contact, chronic disease burden, or comorbidity without evidence of acute instability. 3.2.2 Research Configuration For all research trials, every tool call enforced temporal correctness by including a parameter set to the readingâs original timestamp, ensuring the agent accessed only data available at the time the reading was taken. The agent received only raw vital sign values, patient identifiers, and reading metadata; it did not receive prior data quality-control filter results or prior trial outputs. Each trial was fully independent with no cross-trial memory. The agent operated with a maximum of 15 reasoning turns per trial and a 120- second timeout. 3.3 Study 1: Agent Inter-Rater Reliability To assess the stability of the AI agent triage, we conducted a multi-run inter-rater reliability study treating each independent execution of the AI agent as a separate ârater.â One hundred random vital sign device readings were drawn from AnsibleHealthâs production database, comprising 34 blood pressure cuff readings, 33 pulse oximeter readings, and 33 body weight readings, spanning 92 unique patients. Each device reading was independently triaged 5 times by separate AI agents, yielding 500 total trials. The agent used the 4-level classification scheme (EMERGENCY/URGENT/MONITOR/NOT AN ISSUE) as defined in Section 3.2.1. The primary outcome was Fleissâ kappa coefficient for the four-level classification across 5 raters, with 95% confidence intervals computed via 2,000 bootstrap resamples. Because the four triage levels are ordinal, we also calculated linearly weighted Fleissâ kappa to account for the severity of disagreements. Secondary outcomes included the perfect agreement rate (all 5 runs identical), per-vital-type agreement, and operational metrics. 3.4 Study 2: Agent vs. Rule-Based Baselines We compared the agentâs triage decisions against two rule-based baseline systems on the same 500 readings: a (1) Fixed Threshold Baseline, and an (2) Adaptive Baseline. The Fixed Threshold Baseline combined clinical guideline cutoffs, 43 heart failure rules-of-thumb, 44 and persistence rules, 45 producing a 2-level output (URGENT/NOT AN ISSUE). As a secondary fixed comparator, we included a modified National Early Warning Score 2 (NEWS2), 46 adapted for the limited parameters available from home RPM devices, producing a 4-level classification (EMERGENCY/URGENT/MONITOR/NOT AN ISSUE). The Adaptive Baseline used a rolling 30-day z-score detector with patient-specific statistical bounds to generate a 4-level classification (EMERGENCY/URGENT/MONITOR/NOT AN ISSUE). The primary outcome was alert volume (rate), and the secondary outcomes were agreement between agent and baseline systems. Full baseline specifications and the threshold search strategy are provided in the Appendix. 3.5 Study 3: Agent vs. Human Clinician Validation 3.5.1 Study Design Six clinical reviewers (3 physicians: MD1, MD2, MD3; 3 nurse practitioners: NP1, NP2, NP3) independently graded the same 500 RPM readings using the 4-level classification scheme (EMERGENCY/URGENT/MONITOR/NOT AN ISSUE). The study used a connected matrix design: each sample was independently assigned to 3 of the 6 reviewers, and each reviewer graded 330 total readings (250 unique samples plus 20 anchor samples presented multiple times for intra-rater reliability assessment). Reviewers were blinded to each otherâs annotations and to all automated algorithm decisions. Reviewers accessed a structured clinical interface displaying the vital sign reading alongside comprehensive patient context: interactive 30-day vital sign trend charts, the patientâs active problem list (ICD-10-coded conditions), hospitalization history, clinical notes from the preceding 12 months, and recent patient call summaries. Reviewers had unlimited time for each assessment. A key methodological challenge in evaluating any AI triage system is the absence of a definitive reference standard. Unlike diagnostic tests with objective ground truth (e.g., biopsy-confirmed pathology), clinical triage severity is inherently subjectiveâreasonable clinicians routinely disagree on the appropriate level of escalation for identical patient presentations, particularly in RPM triage with its limited information. Clinical follow-up results of the triage would provide some confirmation, albeit still with subjectivity. However, such follow-up of isolated RPM vitals is impracticable retrospectively. To rigorously validate Sentinelâs performance despite this âreference standard problem,â we employed a three-pronged strategy. First, we quantified human inter-reviewer agreement and intra-rater reliability (Section 3.5.2) to establish the ceiling and variability of human performance, contextualizing agent- human disagreements within the range of clinician-to-clinician disagreement. Second, we conducted a leave-one-out (LOO) analysis (Section 3.5.3) that constructs an independent reference standard for each reviewerâhuman and AI alikeâso the agent is evaluated using the same methodology applied to each individual clinician rather than being compared against a consensus it had no role in forming. Third, all cases where the agent severely escalated beyond the human majority underwent independent clinical adjudication (Section 3.5.4) to determine whether these disagreements represented algorithmic error or clinically defensible escalation. Together, these three validation layers pressure-test the agentâs results from complementary anglesâdemonstrating the degree of human subjectivity, enabling fair head-to-head comparison, and directly interrogating the clinical validity of every agent disagreement. 3.5.2 Endpoints The primary reference standard was established using a majority vote among the three assigned reviewers for each case. Primary endpoints included agreement between the agent and the human majority vote (both exact 4-class and binary [alert vs. not alert]), sensitivity (recall), precision (PPV), specificity, negative predictive value (NPV), false positive rate (FPR), and false negative rate (FNR). Disagreements were further analyzed to quantify the frequency and direction of any agent undertriage or overtriage (e.g., agent: monitor; human: emergency). Secondary endpoints included human inter-reviewer agreement, intra-rater reliability, and triage duration to contextualize the agentâs performance against the inherent subjectivity of the clinical task. 3.5.3 Leave-One-Out Individual Clinician Analysis The majority-vote reference standard, while conventional, introduces a structural asymmetry: the agent is compared against a consensus of three clinicians, but individual clinicians are evaluated as part of that same consensus. A clinician who systematically undertriages may still achieve high âagreementâ with the majority if the other two reviewers happen to align with their assessment. The leave-one-out analysis corrects this asymmetry by constructing an independent reference standard for each clinician: for a given sample, the LOO majority is formed from the two reviewers who did not include the clinician being evaluated. This places every raterâhuman and AI alikeâon equal methodological footing, each judged against a reference standard they did not help create. Samples where the remaining two reviewers disagreed (no majority exists) were excluded from that clinicianâs LOO evaluation. The agent was then evaluated against the identical LOO reference standards, enabling direct head-to-head comparison of individual clinician performance versus the agent on the same cases with the same evaluation criteria. This design is critical because it reveals whether the agentâs sensitivity and specificity are genuinely superior to individual clinicians or merely an artifact of comparison against a pooled consensus that smooths over individual variation. Across the six clinicians, exclusion due to reviewer disagreement ranged from 35.6% to 46.0% of each clinicianâs 250 assigned samples (LOO evaluable N per clinician: 135â161), reflecting substantial baseline disagreement among human reviewers on ambiguous cases. The agent was evaluated against the same LOO subsets. 3.5.4 Clinical Adjudication of Agent Overtriage Cases Of the 105 agent overtriage cases (where the agent rated higher than the human majority by â„1 severity level), we prioritized the 17 most severe disagreementsâcases where the agent exceeded the majority by â„2 severity levelsâfor independent human expert adjudication. Single-level disagreements (N=88) fall within the demonstrated range of inter-clinician variability (clinician exact agreement 59.7%, Section 4.3) and represent adjacent severity categories where reasonable clinicians routinely disagree. Human expert adjudication was therefore reserved for cases where, if the agent were wrong, the clinical consequences would be most significant. Two independent physician reviewers, blinded to each otherâs assessments, independently re-graded each of the 17 cases using the same 4-level classification scheme (EMERGENCY/URGENT/MONITOR/NOT AN ISSUE). Both reviewers had access to the vital sign reading, interactive 30-day vital sign trend charts, the patientâs active problem list, clinical notes, the agentâs full reasoning with cited data sources, and the original reviewer classifications. Each case was then classified into one of three categories by comparing the adjudicatorâs re-grade to both the agentâs classification and the original human majority vote: JUSTIFIED (adjudicator matched or exceeded the agentâs severity level, indicating the agentâs escalation was clinically appropriate), DEBATABLE (adjudicator upgraded from the original majority but assigned a severity level below the agent, indicating the majority was too conservative but the agent may have over-escalated), or TRUE OVERTRIAGE (adjudicator agreed with the original majority vote, confirming the agentâs escalation was not clinically warranted). As a complementary analysis covering all 105 overtriage cases, we performed an automated disagreement characterization using two independent large language models (Claude Opus 4.6 and Gemini 3.1 Pro) to systematically categorize the clinical phenotypes underlying the agentâs overtriage. Rather than rendering binary justified/unjustified verdicts, this automated analysis focused on identifying the recurring clinical patterns that drove agent-human disagreement. 4. Results 4.1 Agent Self-Consistency (Study 1) The agent achieved a Fleissâ kappa of 0.850 (95% CI: 0.786â0.909) for the four-level classification across 5 independent runs on 100 samples, indicating almost perfect agreement by Landis-Koch criteria. 47 All confidence intervals were computed via 2,000 bootstrap resamples (resample size=100 readings, with replacement). Perfect five-way agreement (identical classification across all 5 runs) was achieved on 83 of 100 samples (83%). Table 3. Agent Self-Agreement: Fleissâ Kappa (N=100, 5 runs). Overall Fleissâ Îș (4-level): 0.850. Perfect 5/5 agreement: 83%. Category Fleissâ Îș (95% CI) Distribution (% of 500 runs) Emergency 0.798 (0.370â1.000) 18 (3.6%) Urgent 0.621 (0.326â0.811) 34 (6.8%) Monitor 0.842 (0.761â0.913) 166 (33.2%) Not an issue 0.923 (0.868â0.971) 282 (56.4%) Overall 0.850 (0.786â0.909) 500 (100%) 4.2 Rule-Based Baseline Comparison (Study 2) On the 500-reading subset, the fixed threshold baseline flagged 55.8% of readings as urgentâa rate 1.7 times higher than the agentâs combined urgent and emergency rate of 33.2% (Table 4). Notably, the agent classifies 12.6% of readings as emergency (vs. the fixed thresholdâs 0%) and 20.6% as urgent, reflecting its sensitivity to high-acuity readings that rule-based systems miss entirely. The adaptive baseline was the most conservative, flagging only 9.4% as urgent or emergency. The agent used its four-level classification to differentiate clinically, with 20.2% classified as monitorâreadings warranting review but not same- day action. Table 4. Alert Rate Comparison: Fixed Threshold vs. Adaptive vs. Agent (N=500) System URGENT/EMERGENCY MONITOR NOT AN ISSUE Fixed threshold 279 (55.8%) 57 (11.4%) 164 (32.8%) Adaptive 47 (9.4%) 63 (12.6%) 390 (78.0%) Agent 166 (33.2%) 101 (20.2%) 233 (46.6%) Note: On the same 500 readings, the fixed threshold classified 55.8% as urgent/emergency compared to the agentâs 33.2%, while the adaptive baseline classified only 9.4% as urgent/emergency. These alert rate differences are contextualized in Section 4.4.2 against the human majority-vote reference standard. 4.3 Human Clinician Performance and Reliability (Study 3) To contextualize the agentâs performance, we first assessed the reliability of the human reviewers. 4.3.1 Intra-Rater Reliability Each reviewer re-graded 20 of their own samples. Pairwise exact agreement averaged 75.8% (range: 55%â95%). Table 5. Intra-Rater Reliability. 20 unique samples per reviewer, repeated 5 times. Reviewer Exact Match Percentage MD1 11/20 55.0% MD2 18/20 90.0% MD3 17/20 85.0% NP1 12/20 60.0% NP2 14/20 70.0% NP3 19/20 95.0% Mean 15.2/20 75.8% By comparison, the agent achieved 83% perfect five-way agreement in Study 1âexceeding the self- consistency of most individual human reviewers. 4.3.2 Inter-Reviewer Agreement Pairwise exact agreement between any two clinicians on the same sample averaged 59.7% (range: 46.2%â 69.1%), highlighting the inherent subjectivity of RPM triage (Figure 3). Reviewer consensus (all 3 reviewers unanimous) was achieved on 42.8% (214/500) of samples (Table 6). Three-way splits (all 3 reviewers selecting different triage levels) occurred on 6.6% (33/500) of samples. Figure 3. Inter-Reviewer Pairwise Exact Agreement Matrix. Average agreement of 15 inter-reviewer pairs was 59.7% (range: 46.2%â69.1%), and the average agreement of agent-reviewer pairs was 62.1% (range: 50.4%â68.0%). Table 6. Inter-Reviewer Agreement Distribution Metric Value Mean pairwise exact agreement 59.7% (range: 46.2%â69.1%) Unanimous consensus (3/3) 214/500 (42.8%) Majority consensus (â„2/3) 467/500 (93.4%) Three-way split 33/500 (6.6%) 4.3.3 Reviewer vs. Agent Agreement Pairwise agreement between individual reviewers and the agent averaged 62.1%, ranging from 50.4% to 68.0% (Table 7). This exceeded the average inter-reviewer agreement of 59.7% by 2.4 percentage points, indicating that humans agreed with the agent slightly more than they agreed with each other. Binary agreement (actionable vs. non-actionable) averaged 83.5%. Table 7. Reviewer-Agent Pairwise Agreement Reviewer Exact Agreement Binary Agreement Within ±1 MD1 163/250 (65.2%) 210/250 (84.0%) 236/250 (94.4%) MD2 170/250 (68.0%) 211/250 (84.4%) 236/250 (94.4%) MD3 162/250 (64.8%) 212/250 (84.8%) 235/250 (94.0%) NP1 148/250 (59.2%) 206/250 (82.4%) 238/250 (95.2%) NP2 126/250 (50.4%) 210/250 (84.0%) 241/250 (96.4%) NP3 163/250 (65.2%) 204/250 (81.6%) 232/250 (92.8%) Average 62.1% 83.5% 94.5% 4.4 Agent vs. Human Majority Vote Reference Standard Figure 4. Agent vs. Human Majority Vote Confusion Matrix (N=467) Thirty-three samples with three-way splits among reviewers (no majority vote) were excluded from accuracy analyses, yielding an evaluable set of 467 samples. Table 8 summarizes agent performance against the majority-vote reference standard; these metrics should be interpreted with the caveat that the reference standard itself carried substantial uncertainty (clinician unanimity on only 42.8% of samples; see Section 4.3.2), and that the agent or a minority reviewer may have been correct in cases scored as disagreements. Overall, four-level exact accuracy was 69.4% (324/467), with a quadratic-weighted kappa of 0.778 (substantial agreement; 95% CI: 0.728â0.819) and 95.9% of classifications falling within one severity level of the reference standard. Per-category recall (Table 9) demonstrated strong detection of high-acuity readings: emergency sensitivity reached 95.8% (23/24) and urgent recall was 56.3% (45/80). The agentâs disagreement profile favored overtriage over undertriage: agent overestimation of severity (relative to human majority) occurred in 105 cases (22.5%) versus underestimation in 38 cases (8.1%), a ratio of 2.8:1 favoring clinical caution. Table 8. Agent Performance vs. Majority Vote Reference Standard (N=467). Thirty-three samples with three-way splits among reviewers (no majority vote) were excluded from analysis. Metric Value Four-level exact accuracy 324/467 (69.4%) Quadratic-weighted kappa 0.778 (95% CI: 0.728â0.819) Within ±1 severity level 448/467 (95.9%) Overtriage cases 105/467 (22.5%) Undertriage cases 38/467 (8.1%) Table 9. Agent Per-Category Performance vs. Majority-Vote Reference Standard (N=467) Category Reference Standard Prevalence Recall Precision EMERGENCY 24 (5.1%) 23/24 (95.8%) 23/56 (41.1%) URGENT 80 (17.1%) 45/80 (56.3%) 45/88 (51.1%) MONITOR 121 (25.9%) 53/121 (43.8%) 53/93 (57.0%) NOT AN ISSUE 242 (51.8%) 203/242 (83.9%) 203/230 (88.3%) Under the clinically critical binary threshold (Actionable: EMERGENCY+URGENT vs. Non-Actionable: MONITOR+NOT AN ISSUE), the agent achieved 88.5% sensitivity (92/104), 85.7% specificity (311/363), 63.9% PPV (92/144), and 96.3% NPV (311/323). The high NPV indicates that when the agent classifies a reading as non-actionable, it is correct 96.3% of the time (Table 10). Table 10. Binary Classification Performance: Actionable vs. Non-Actionable (N=467) Metric Actionable (E+U vs. M+NI) Accuracy 403/467 (86.3%) Sensitivity 92/104 (88.5%) Specificity 311/363 (85.7%) Positive Predictive Value (PPV) 92/144 (63.9%) Negative Predictive Value (NPV) 311/323 (96.3%) When evaluated against the max-severity reference standard (the highest severity assigned by any of the 3 reviewers, all 500 samples), the agent achieved 80.0% actionable sensitivity and 92.0% specificity, demonstrating robustness even against the most conservative human benchmark. 4.4.1 Comparison of Agent vs. Rule-Based Baselines Against Human Majority Vote Reference Standard To contextualize the agentâs performance, we evaluated the same 467 samples against the two rule-based baselines described in Study 2 (fixed threshold with modified NEWS2 and adaptive statistical baseline). Table 11 presents a head-to-head comparison on the key metrics; full per-system confusion matrices are provided in Appendix Tables A1 and A2. Table 11. Head-to-Head Performance: Agent vs. Rule-Based Baselines Against Majority-Vote Reference Standard (N=467) Metric Agent Fixed Threshold Adaptive Four-level exact accuracy 324/467 (69.4%) 250/467 (53.5%) 234/467 (50.1%) Actionable sensitivity (E+U) 92/104 (88.5%) 102/104 (98.1%) 19/104 (18.3%) Specificity (M+NI) 311/363 (85.7%) 215/363 (59.2%) 341/363 (93.9%) PPV 92/144 (63.9%) 102/250 (40.8%) 19/41 (46.3%) NPV 311/323 (96.3%) 215/217 (99.1%) 341/426 (80.0%) QWK 0.778 (95% CI: 0.728â0.819) 0.573 (95% CI: 0.506â0.614) 0.235 (95% CI: 0.218â0.385) The three systems exhibited strikingly different operating points on the sensitivity-specificity trade-off. The agent achieved the best balance: 88.5% actionable sensitivity with 85.7% specificity (QWK 0.778 [95% CI: 0.728â0.819]), compared to the fixed thresholdâs 98.1% sensitivity at only 59.2% specificity (QWK 0.573 [95% CI: 0.506â0.614]) and the adaptive baselineâs 93.9% specificity at only 18.3% sensitivity (QWK 0.235 [95% CI: 0.218â0.385]). The agentâs NPV (96.3%) approached the fixed thresholdâs (99.1%), indicating that both systems rarely missed actionable cases, but the agent accomplished this without the fixed thresholdâs overwhelming false-positive burden. The fixed threshold baseline achieved the highest actionable sensitivity (98.1%) but at the cost of flagging 53.5% of all readings as urgentâgenerating 2.8 times as many false positives as the agent (148 vs. 52)â and only 40.8% PPV. The adaptive baseline showed the opposite failure mode: although its specificity (93.9%) exceeded the agentâs, its actionable sensitivity was only 18.3%, missing over 80% of clinician- identified actionable casesâa result of its reliance on patient-specific rolling statistics that normalized chronically abnormal values as within-range. 4.5 Individual Clinician vs. Agent Performance (Leave-One-Out Analysis) To move beyond aggregate majority-vote comparison, we conducted a leave-one-out (LOO) analysis comparing each individual clinicianâs performance against the agent on identical evaluation criteria. Table 12 presents each clinicianâs performance against the two-reviewer reference across all of their assigned samples, as well as the pool of all 6 cliniciansâ subsets to show agentâs performance against the two-reviewer reference. The full per-clinician details of agentâs LOO performance are included in Appendix Table A4. Table 12. Leave-One-Out Analysis: Individual Clinician vs. Agent Performance. Agentâs LOO performance metrics are presented for an aggregated pool of all 6 cliniciansâ assigned samples. Reviewer LOO Samples Exact Match Emergency Sensitivity Actionable Sensitivity Overtriage Rate MD1 154 74.0% 7/9 (78%) 25/30 (83%) 16.2% MD2 135 79.3% 4/6 (67%) 14/22 (64%) 5.2% MD3 153 78.4% 4/5 (80%) 16/26 (62%) 10.5% NP1 161 66.5% 4/6 (67%) 16/30 (53%) 20.5% NP2 149 58.4% 1/8 (13%) 20/21 (95%) 33.6% NP3 143 74.8% 4/6 (67%) 16/25 (64%) 10.5% Agent 895 (agg.) 75.5% 39/40 (97.5%) 140/154 (90.9%) 18.9% Figure 5. Leave-One-Out Analysis: Individual Clinician vs. Agent Performance The LOO analysis revealed that the agent outperformed every individual clinician on emergency sensitivity (97.5% vs. clinician range 13%â80%, aggregate 60.0%) and actionable sensitivity (90.9% vs. clinician range 53%â95%, aggregate 69.5%). The agentâs exact match rate (75.5%) was comparable to most clinicians (range 58.4%â79.3%). Emergency sensitivity showed the most striking contrast: the best individual clinician detected 80% of emergencies, while the agent detected 97.5%. Only one clinician (NP2) achieved higher actionable sensitivity (95%), but at the cost of a 33.6% overtriage rateâthe highest of any raterâand the lowest emergency sensitivity (13%). This analysis demonstrates that the agent functions as a safety net that exceeds any individual clinicianâs vigilance for critical deterioration. The agentâs overtriage rate (18.9%) was moderateâlower than NP1 (20.5%) and NP2 (33.6%)âsuggesting that its elevated sensitivity does not come at an unacceptable cost in false escalations. 4.6 Clinical Adjudication of Agent Overtriage Cases Of 467 evaluable readings, agent-human disagreements skewed toward overtriage (105 cases, 22.5%) rather than undertriage (38 cases, 8.1%)âa 2.8:1 ratio favoring clinical caution. To determine whether the agentâs most severe overtriage cases represented genuine algorithmic error or clinically defensible escalation, two independent physician reviewers re-graded the 17 cases where the agent exceeded the human majority by â„2 severity levels (Section 3.5.4). Results are presented in Table 13. Table 13. Human Expert Adjudication of Severe Agent Overtriage Cases (AgentâMajority Gap â„2 Levels; N=17) Category Expert 1 Expert 2 Final Decision JUSTIFIED (adjudicator matched or exceeded agent) 7 (41%) 11 (65%) 11 (65%) DEBATABLE (adjudicator upgraded from majority, below agent) 8 (47%) 5 (29%) 6 (35%) TRUE OVERTRIAGE (adjudicator agreed with human majority) 2 (12%) 1 (6%) 0 (0%) Total non-overtriage (JUSTIFIED + DEBATABLE) 15 (88%) 16 (94%) 17 (100%) Both adjudicators independently validated the agentâs escalation in 88â94% of the severe disagreement cases, confirming that the agentâs clinical judgement was defensible in the vast majority of instances. Notably, neither adjudicator graded any of these 17 cases as ânot an issueââdespite the original majority voting ânot an issueâ on 9 of the 17 cases (53%). True overtriage, where the adjudicator disagreed with the agentâs escalation, was rare: 2 of 17 cases (12%) for Reviewer 1 and 1 of 17 cases (6%) for Reviewer 2. Following independent review, the two adjudicators jointly resolved all 17 cases through consensus discussion, classifying 11 (65%) as JUSTIFIED, 6 (35%) as DEBATABLE, and 0 (0%) as TRUE OVERTRIAGEâyielding a 100% non-overtriage rate and confirming that none of the agentâs most severe escalations represented genuine algorithmic error. As a complementary analysis of all 105 overtriage cases, automated disagreement characterization by two independent large language models identified five recurring clinical phenotypes underlying the agentâs escalations: (1) hemodynamic lability (25 cases)âlarge systolic swings flagged as dangerous even when the current absolute value was benign; (2) trend-based escalation (20 cases)âmulti-day worsening trajectories invisible in a single reading; (3) SpOâ on supplemental Oâ (15 cases)âthe agent correctly noted that desaturation while on supplemental oxygen carries different clinical significance than the same SpOâ on room air; (4) post-discharge vulnerability (12 cases)âescalation based on readmission risk in recently discharged patients; and (5) clinical oversight gaps (~15 cases)âescalation when no clinical contact had occurred for weeks in medically complex patients. These phenotypes describe what the agentâs overtriage looks like clinically, providing actionable categories for system refinement. 4.7 Operational Metrics Table 14 compares operational cost and throughput across the two agent studies. The agentâs per-triage cost ranged from $0.32 to $0.34, with zero failures across all 1,000 trials. Figure 6 illustrates a resource gradient of 500-trial run (Study 2, 3) by alert severityâthe agent invested progressively more reasoning effort (more tool calls, longer processing, higher cost) for higher-acuity readings, consistent with appropriate clinical diligence rather than uniform processing. Table 14. Operational Metrics by Study Metric Study 1: Agent IRR Study 2,3: Agent vs. Human Trials 100 x 5 runs 500 x 1 run Cost per trial (mean) $0.32 $0.34 Total cost $157.89 $172.36 Duration (median) 98.7 sec 94.5 sec (IQR 71.4â131.4) Agent turns (mean) 11.5 12.5 Output tokens (mean) 4,061 3,956 Failure rate 0/500 (0.0%) 0/500 (0.0%) Figure 6. Tool Usage Gradient by Alert Severity 4.8 Duration of Triage The agent completed triage in a median of 94.5 seconds (IQR 71.4â131.4 s) per reading (Table 15). Human clinician reviewers completed triage in a median of 7.0â28.0 seconds per reading, depending on the reviewer. These durations were not directly comparable: the human review task was limited to assigning a four-level triage classification given a pre-assembled data summary that included the patientâs vital sign history, active conditions, medications, and recent encounters, whereas the agent independently retrieved and synthesized clinical data from 21 MCP tools before rendering its assessment. The human durations therefore excluded the chart review and data gathering time that would be required in a real clinical workflow. Table 15. Duration of Triage: Agent vs. Human Reviewers Reviewer Median (s) IQR (s) Sentinel Agent 94.5 71.4â131.4 MD1 10.5 6.0â18.0 MD2 12.0 4.3â28.0 MD3 7.0 4.0â14.0 NP1 28.0 16.0â47.0 NP2 24.0 12.0â41.0 NP3 25.5 16.0â50.8 4.9 Case Examples The following anonymized cases illustrate how comprehensive context retrieval shapes triage accuracy, highlighting both agent-clinician agreement and cases where the agentâs contextual reasoning identified clinical concerns that human reviewers missed. For each case, we report the vital sign reading, reviewer classifications, and the agentâs reasoning. 4.9.1 Agent-Human Agreement on High-Acuity Cases Case A (Emergency Agreement): BP 202/95, HR 87. Human majority: emergency. Agent: emergency (12 tool calls, 156 seconds). Figure 7. Case Example A A blood pressure of 202/95 might be dismissed as chronic uncontrolled hypertension in a patient with repeatedly elevated readings above 200. The agent distinguished the acute component: an 81 mmHg systolic surge in 24 hours, two consecutive readings â„200 (227/103 followed by 202/95, both resting), and the imminent end-organ risk in a 68-year-old post-NSTEMI patient with CKD Stage 3 and documented medication non-adherence. The agent noted âboth readings confirm this is sustained severe hypertension, not a transient spikeâ and âno clinical outreach has occurred since Feb 5 (13 days ago).â This case illustrates how the agent distinguishes acute-on-chronic deterioration from chronic baseline through trend analysis and temporal context. Case B (Emergency Agreement): BP 80/57, HR 69. Human majority: emergency. Agent: emergency (23 tool calls, 273 seconds). Figure 8. Case Example B A blood pressure of 80/57 in a 68-year-old patient with orthostatic hypotension on midodrine might appear to be a known chronic pattern. The agent's extensive investigation revealed a critical distinction: the BP showed progressive exercise-induced decline (95â86â80 over 45 minutes)âan ABNORMAL hemodynamic response indicating the heart cannot augment cardiac output to meet metabolic demand. The agent identified that HR 69 could represent chronotropic incompetence (peak exercise HR only 55% of age-predicted max) and that the patient would return to an unsupervised home environment where similar events could cause syncope or organ injury. The agent applied the principle that vitals taken under clinical supervision must be evaluated for their implications in an unmonitored home setting. Case C (Urgent Agreement): SpO2 87%, HR 69. Human majority: urgent (unanimous). Agent: urgent (16 tool calls, 209 seconds). Figure 9. Case Example C An SpO2 of 87% during a supervised exercise session might be dismissed as expected exercise desaturation, particularly when the attending clinician documented âsafety parameters within acceptable limits.â The agent identified that the 87% reading occurred during a transition between video sessions (not at peak exertion), making it more concerning. The agent further noted the patientâs last known resting SpO2 was 94% two months earlier, representing a 7-point decline, and that peak HR of only 70 bpm (48% of age-predicted target) without beta-blocker use indicated chronotropic incompetence. This case demonstrates the agentâs ability to reframe supervised exercise data through the lens of unsupervised home risk. 4.9.2 Agent Escalates Beyond Human Majority â Justified Overtriage Case D (Agent Escalates: Monitor â Emergency): BP 172/117, HR 59. Human majority: monitor. Agent: emergency (10 tool calls, 162 seconds). Adjudication: both reviewers agreed with emergency. Figure 10. Case Example D The human majority classified this as monitor. The agent escalated to emergency after identifying a convergence of alarming findings in this 82-year-old female with HFpEF, CKD stage 3b-4, severe COPD on supplemental oxygen, and a hospitalization for acute respiratory failure two months prior. The agent flagged concurrent abnormalities: (1) the marked diastolic hypertension of 117 mmHg represented a +36 mmHg surge from the patientâs baseline of ~79, approaching hypertensive emergency territory and threatening acute kidney injury in a patient with CKD and AKI history; (2) acute relative bradycardiaâ the pulse 59 was a 52 bpm drop from the most recent reading of 111, far below the patientâs average of 95, raising concern for conduction disease or a medication effect during an unreconciled medication period; and (3) an absence of clinical oversight for 6 days despite the care teamâs documented concern about the patientâs blood pressure. The agent explicitly invoked its tie-breaker principle: âIf immediate safety risk is uncertain but possible, choose EMERGENCY.â Both independent adjudicators agreed with emergency driven primarily by the hypertensive urgency, confirming the clinical validity of the agentâs escalation. Case E (Agent Escalates: Not an Issue â Urgent): Weight 72.05 kg. Human majority: not an issue. Agent: urgent (12 tool calls, 85 seconds). Adjudication: Reviewer 1 agreed with urgent; Reviewer 2 escalated to emergency. Figure 11. Case Example E A weight of 72.05 kg in isolation conveys no clinical information. The human majority classified this as not an issue. The agent identified that this 87-year-old femaleâwith documented peripheral edema, orthopnea, diuretic therapy, and two recent hospitalizationsâhad been discharged just one day earlier, and her weight had surged from a stable baseline of 66.75â68.8 kg to 72.05â72.7 kg: a gain of 11.6â13.1 lbs in approximately two days, representing an ~8â9% body weight increase characteristic of acute fluid retention. The agent synthesized supporting evidence: same-day SpO2 of 90% (below her usual 92â96% range), blood pressure elevated to 135/75 from a recent range of 89â119 systolic, and no clinical contact in over three weeks. The agent noted this âapproaches EMERGENCY thresholdâ but classified as urgent because the patient was exercising with stable hemodynamics and the trajectory was over days rather than hoursâa deliberate calibration between severity levels. Both adjudicators validated the agentâs escalation. 5. Discussion This study demonstrates three principal findings. First, autonomous AI agents can perform reliable, contextual clinical triage of RPM vital signs with consistency exceeding that of individual human clinician reviewers. Second, the agent prioritizes patient safety through a calibrated overtriage profile, catching clinical deterioration more reliably than individual cliniciansâunder the studyâs evaluation conditions, in which clinicians reviewed pre-assembled context summaries while the agent dynamically retrieved longitudinal dataâwhile maintaining a manageable alert volume. Third, Sentinelâs standards- based architecture provides a scalable path toward the intensive monitoring model that TIM-HF2 18 proved saves lives. The practical impact of this work is immediate: both conventional approaches to RPM alerting failed when evaluated against clinician judgment. The fixed threshold baseline flagged 53.5% of readings as urgent yet achieved only 59.2% specificity and 40.8% PPVâan alert burden so high it reproduces the undifferentiated data flood that overwhelmed clinical staff in the failed RPM trials. The adaptive statistical baseline exhibited the opposite failure: by normalizing chronically abnormal values as within- range, it missed 81.7% of clinician-identified actionable cases and achieved only 50.1% four-level accuracy, functionally equivalent to chance. The agent outperformed both, achieving 69.4% four-level accuracy, 88.5% actionable sensitivity, and 85.7% specificityâthe best balance of sensitivity and specificity, with a QWK of 0.778 (95% CI: 0.728â0.819) versus 0.573 (95% CI: 0.506â0.614) and 0.235 (95% CI: 0.218â0.385) for the two baselines. The agent applied contextual reasoning rather than rigid cutoffs. For example, blood pressure of 80/57 appears to be a hypotensive emergency; the agent validated this emergency by identifying a progressive exercise-induced decline indicating inability to augment cardiac output, chronotropic incompetence, and the danger of similar events in an unsupervised home setting. Similarly, SpO2 of 83% in a patient with severe COPD might appear routine given the patientâs chronic hypoxemia; however, the agent escalated to emergency after identifying a progressive 3-hour desaturation trajectory with compensatory tachycardia, distinguishing an active decline from a stable chronic baseline. Conversely, the same absolute values in patients with documented chronic patterns and no acute trajectory were appropriately triaged at lower severity. Unlike static baselines, the agent applies context-specific thresholds to individual patient trajectories, yielding a higher proportion of actionable alerts compared to conventional rule-based systems. The agentâs overtriage profile must be understood in the context of the data flood problem that dominates RPMâs history of failure. Importantly, the nature of the agentâs overtriage differs qualitatively from threshold-based false positives. The five clinical phenotypes identified in the disagreement characterizationâhemodynamic lability, trend-based escalation, supplemental oxygen context, post- discharge vulnerability, and clinical oversight gapsârepresent contextualized clinical judgments, not indiscriminate threshold crossings. When a clinician receives an agent-generated urgent alert citing a 50- mmHg systolic swing in 24 hours, this conveys actionable clinical information even if the clinician ultimately disagrees with the severity classification; by contrast, a threshold alert stating âBP > 140â for a patient with chronic uncontrolled hypertension conveys nothing new and erodes trust. The agentâs 2.8:1 overtriage-to-undertriage ratio (105 vs. 38 cases) reflects a deliberate tilt toward patient safety that aligns with established clinical principles: in the tradeoff between missed emergencies and excess alerts, the consequences of undertriage are irreversible while the consequences of overtriage are manageableâ provided the alert volume remains within clinical capacity. The data indicate that Sentinel achieves this balance. The system evaluated readings with a median processing time of 94.5 seconds and an API cost of $0.34 per reading. In leave-one-out analysis, the agent detected 97.5% of emergencies and 90.9% of actionable casesâexceeding the sensitivity of every individual clinician on both metrics. These findings suggest that LLM-based agents can conduct contextual triage of vital signs with sensitivity comparable to or exceeding that of individual clinicians in retrospective evaluation, offering a potentially scalable approach to RPM triage. 5.1 Comparison with Clinician Performance The data indicate that the agentâs performance metrics exceed those of individual human reviewers in this specific triage task across multiple measures. First, the agentâs reliability exceeds that of most human reviewers. The agentâs self-consistency is exceptionally high (Fleissâ Îș = 0.850 [95% CI: 0.786â0.909], almost perfect agreement), achieving perfect five-way agreement on 83% of repeated evaluations. In contrast, human intra-rater reliability averaged 75.8% but varied widely (55%â95%), with some reviewers consistent on barely half their samples. When compared against the clinical panel, the agentâs agreement with individual reviewers (62.1%) fell squarely within the range of inter-human agreement (59.7%), demonstrating that its judgments align with the zone of professional consensusâwhile substantially reducing the extreme subjectivity that produced a 20-fold variation in emergency classification rates across reviewers (0.8%â 16.0% on 250 unique samples). Second, the leave-one-out analysis revealed that the agent outperforms every individual clinician on the metrics that matter most for patient safety. The agent detected 97.5% of emergencies versus a clinician aggregate of 60.0% (range 13%â80%), and 90.9% of actionable cases versus 69.5% (range 53%â95%). No individual clinician matched the agent on both emergency and actionable sensitivity simultaneously. In this cohort, the agentâs sensitivity for both emergency and actionable cases was higher than the maximum sensitivity achieved by any individual clinician on the panel, while maintaining an overtriage rate (18.9%) lower than two of the six clinicians. The explanation lies not in clinical skill but in the consistency of context retrieval. The six human reviewers had unlimited time and access to the same categories of clinical data as the agent. Yet the critical difference was not data availability but data utilization: the agent accessed an average of 10.1 clinical data tools for every single reading, without variation. An important caveat applies: the human reviewers evaluated isolated readings with pre-assembled context summaries, while the agent retrieved and synthesized context dynamically. This task differenceâcross-sectional evaluation versus longitudinal synthesisâmay account for some of the performance gap. We hypothesize this performance gap may stem in part from task framing: clinicians evaluating isolated data summaries may lower their threshold for escalation under uncertainty, while the agentâs architecture structurally prompts it to query additional patient context before outputting a classification. 5.2 Clinical Validity of Agent Disagreements The agentâs overtriage profileâ105 cases (22.5%) versus 38 undertriage cases (8.1%), a 2.8:1 ratio favoring clinical cautionâraises the central question of whether these escalations represent algorithmic error or clinically defensible judgment. The human expert adjudication of the 17 most severe disagreement cases (agentâmajority gap â„2 levels) provides a preliminary answer: both independent physician reviewers validated the agentâs escalation in 88â94% of cases, with true overtriage confirmed in only 6â12% (Table 13). Subsequent consensus resolution between the two reviewers further strengthened this finding, classifying 0 of 17 cases (0%) as true overtriageâa 100% non-overtriage rate. Neither adjudicator classified any of the 17 cases as ânot an issue,â despite the original majority voting ânot an issueâ on 9 of those 17 cases (53%)âa striking finding that suggests the original clinician reviewer majority systematically underestimated the clinical significance of these readings. These findings establish that the agentâs most extreme disagreements with the human majority are overwhelmingly clinically defensible. When the agent escalates far beyond the consensus, it is not generating false alarmsâit is identifying clinical concerns that the majority overlooked. Only 6 of 467 evaluable readings (1.3%) showed the agent exceeding any individual human reviewer opinion by â„2 severity levels, confirming that extreme overtriage was rare; of those, the adjudication data indicate that the majority of even these extreme cases reflected genuine clinical concern. Automated disagreement characterization of all 105 overtriage cases identified five recurring clinical phenotypes: (1) hemodynamic lability (25 cases)âthe agent flagged large systolic swings (>50 mmHg within hours/days) as dangerous even when the current absolute value was benign; (2) trend-based escalation (20 cases)âmulti-day worsening trajectories invisible in a single reading; (3) SpOâ on supplemental Oâ (15 cases)âthe agent correctly noted that desaturation while on supplemental oxygen is far more concerning than the same SpOâ on room air; (4) post-discharge vulnerability (12 cases)â escalation based on readmission risk in recently discharged patients; (5) clinical oversight gaps (~15 cases)âescalation when no clinical contact had occurred for weeks in medically complex patients. These phenotypes describe what the agentâs overtriage looks like, while the human adjudication confirms that these escalations are largely clinically appropriate. The small proportion of independently confirmed true overtriage (6â12%), which was eliminated entirely upon consensus resolution (0%), was driven by a specific, identifiable pattern: the agent penalizing objectively normal current readings (e.g., BP 121/75) based on historical lability. This pattern represents a tunable parameter in future iterations rather than a fundamental limitationâand its specificity means it can be addressed without compromising the agentâs sensitivity for genuine clinical deterioration. 5.3 Relationship to TIM-HF2 TIM-HF2 demonstrated that structured, responsive, contextualized monitoring reduced heart failure mortality by 30%. 18 The telemedical centerâs efficacy derived not from better thresholds but from clinicians who could synthesize full patient context and act promptly. However, replicating that level of intensive, context-aware human oversight across large patient populations remains economically and logistically challenging. Sentinelâs architecture attempts to approximate this approach computationally. The tool usage data confirm systematic contextual investigation: five core tools (demographics, conditions, medications, encounters, vitals history) were called on 100% of trials, with additional tools called situationally (clinical notes on 54.0% of trials, health information exchange summaries on 29.0%, ICD-10 lookups on 0.4%). Higher-acuity classifications correlated with deeper investigation (EMERGENCY: 14.2 tools vs. NOT AN ISSUE: 8.7 tools), suggesting that the agent performed proportionally thorough evaluation before escalating. Whether this computational approach to contextual triage can replicate TIM-HF2âs clinical outcomes remain an open question requiring prospective validation. 5.4 Scalability Through Standards-Based Architecture A critical architectural feature of Sentinel is its scalability across the U.S. healthcare system. The systemâs clinical data is sourced entirely through Health Information Exchanges (HIEs) via standardized FHIR interfaces rather than direct EHR integration. The MCP tools query HIE-aggregated data that are available for any U.S. patient with HIE-connected providers. This makes Sentinel inherently EHR- agnostic: the same agent, with the same tools, could be deployed at any RPM organization without custom integration. The study population itself reflects this portability, spanning patients across 25 U.S. states and multiple EHR systems, all accessed through a single standardized interface. This architecture aligns directly with ARPA-Hâs ADVOCATE program (January 2026), which explicitly funds agentic AI for cardiovascular care with the goal of nationwide deployment. 48 The technical barriers to scaling Sentinel beyond a single organization are minimalâthe system requires only FHIR-compliant HIE access, which is increasingly mandated by federal interoperability rules. The limiting factor for RPM has never been the monitoring devices; it has been the clinical intelligence layer that interprets the data. Sentinel provides that layer at $0.34 per reading, ready for deployment wherever FHIR-based clinical data is available. 5.5 Addressing Historical RPM Limitations Sentinelâs architecture directly addresses each failure mode from the landmark trials: â Data flood without intelligent filtering. Against clinician majority vote, both rule-based baselines performed near chance: the fixed threshold achieved 53.5% four-level accuracy with only 59.2% specificity, while the adaptive baseline achieved 50.1% accuracy and missed 81.7% of clinician- identified actionable cases (Section 4.4.2). The agent outperformed both (69.4% accuracy, 85.7% specificity, QWK 0.778 [95% CI: 0.728â0.819]) while replacing undifferentiated alert streams with clinically differentiated four-level triage. â The broken loop. The agent generated structured assessments with severity classification and clinical reasoning citing specific data pointsâdesigned to compress the detection-to-action loop that was unbounded in the failed trials, where staff had to triangulate between data reviewers and prescribing clinicians. 13 The agent also produced recommended action types (e.g., clinical review, urgent review, care coordination), though the clinical appropriateness of these action classifications was not validated in this study. Whether the structured output reduced time-to- intervention in practice was not measured. â Lack of contextual interpretation. With 21 clinical tools, the agent performs the deep contextual reasoning absent in failed trials. The agent-reviewer agreement (62.1%) and leave-one-out analysis (97.5% emergency sensitivity, 90.9% actionable sensitivity) suggest that this contextual approach produces triage decisions more aligned with clinician consensus than either rule-based alternative. â Adherence barriers. Sentinel monitors passively by polling for readings patients are already submitting through their existing RPM program. Unlike Tele-HF, 7 which required daily telephone interactions, the system operates passively on existing submitted data, requiring no additional patient interaction. â No population targeting. By identifying high-risk alerts while suppressing non-actionable readings, the agent has the potential to better allocate clinician attention toward patients most likely to benefit from intervention. 5.6 Per-Vital-Type Variability Agreement varied by vital sign type. Blood pressure achieved similar high reliability, and SpO2 readings had the widest confidence interval in the agent inter-rater reliability study (i.e., stability), reflecting the smaller number of abnormal readings in this outpatient population and the complex interpretation of chronic hypoxemia. Weight interpretation required the most contextual reasoningâdistinguishing fluid retention from dietary variation, accounting for diuretic therapy, and recognizing clinically significant changes against patient-specific baselines. This aligns with BEAT-HFâs finding that weight is a poor surrogate when interpreted without clinical context, 8 and highlights the agentâs ability to navigate precisely this challenge. 5.7 Economic Implications Sentinel processes readings at a fraction of the cost of human clinical review. At $0.34 per triage, an organization generating approximately 1,000 readings per day would incur roughly $124,000 annually in AI triage costsâa level of coverage that would otherwise require multiple full-time employees. While there is cost for clinicians to act upon the Sentinel alerts, the substantial time and cost of the triage is markedly minimized. The cost gradient by severity (e.g., NOT AN ISSUE: $0.26, EMERGENCY: $0.47) reflects the agentâs proportional investigation depth, naturally allocating computational resources to clinical complexity. These estimates cover API inference costs only and do not include infrastructure, development, maintenance, or clinical oversight costs. 5.8 Regulatory Landscape Sentinelâs architectureâproviding detailed reasoning chains, cited data sources, and human-in-the-loop oversightâaligns with the FDAâs updated Clinical Decision Support guidance and the emerging regulatory frameworks for LLM-based clinical tools. 49,50 ARPA-Hâs ADVOCATE program, which explicitly funds agentic AI for cardiovascular care, 48 provides additional validation of this regulatory pathway. 5.9 Limitations Several important limitations must be acknowledged. First, performance is specific to the LLM used in this study (claude-opus-4-6); generalizability to other models is unknown. Second, the majority-vote reference standard itself carries substantial uncertaintyâclinician unanimity occurred on only 42.8% of samples, and the agent may be penalized for being more thorough than the human majority in cases where the majority was wrong. This âreference standard paradoxâ means that measured overtriage likely overstates true algorithmic error. Third, this study evaluates reliability and agreement, not clinical outcomesâwhether Sentinelâs triage reduces hospitalizations, emergency department visits, or mortality remains unproven. Fourth, all data originates from a single organization (AnsibleHealth); multi-site validation is needed. Fifth, Sentinelâs action type classification was not evaluated. Sixth, performance was not evaluated across demographic subgroups; potential disparities by age, sex, race, or disease severity are unstudied. Finally, 500 readings from 340 patients introduce patient clustering that may violate statistical independence assumptions. 5.10 Future Work Three directions are planned. First, a prospective clinical outcome study comparing Sentinel-monitored patients, both with and without the agentâs clinical recommendations, against historical controls to evaluate impact on hospitalizations and mortality. Second, multi-model validation with alternative LLMs (e.g., GPT-5.2, Gemini 3.1) to assess model dependence. Additionally, the rapid maturation of conversational voice AI suggests a potential pathway from triage to patient outreach. Connecting a triage agent to voice agents capable of conducting structured clinical conversationsâsymptom assessment, medication reconciliation, and escalation to human clinicians when indicatedâcould further compress the time from alert to clinical action. The agentic architecture described here is designed to support this kind of multi-agent orchestration, though such integration requires separate validation. 6. Conclusion This study demonstrates that a large language model equipped with structured clinical tools can perform reliable, contextual triage of RPM vital signs with sensitivity to clinical deterioration that, in this retrospective evaluation, exceeded that of individual clinicians reviewing pre-assembled context summaries, while maintaining a clinically defensible overtriage profile. The evidence for this capability is multi-layered. Both conventional approaches to RPM alerting demonstrated poor concordance with clinician judgment: the fixed threshold baseline achieved only 53.5% four-level accuracy with 59.2% specificity, while the adaptive statistical baseline achieved 50.1% accuracy and missed 81.7% of clinician-identified actionable cases by normalizing chronically abnormal values. Sentinel outperformed both, achieving 69.4% four-level accuracy, 88.5% actionable sensitivity, and 85.7% specificity (QWK 0.778 [95% CI: 0.728â0.819]). The agent achieved almost perfect self-consistency (Fleissâ Îș = 0.850 [95% CI: 0.786â0.909], 83% perfect 5/5 agreement) and performed within the range of human variability when compared against a panel of six clinicians (62.1% pairwise agreement vs. 59.7% inter-clinician average), while substantially reducing the extreme subjectivity that produced a 20-fold variation in emergency classification rates across individual reviewers. In leave-one-out analysis, the agent detected 97.5% of emergencies versus a clinician aggregate of 60.0%, and 90.9% of actionable cases versus 69.5%âoutperforming every individual clinician on both metrics. When the agent disagreed most severely with the human majority (gap â„2 levels, N=17), independent physician adjudication found that 88â94% of these escalations were clinically justified or debatable, with true overtriage confirmed in only 6â12% of cases. Previous trials highlight that the efficacy of remote patient monitoring is often limited by alert fatigue and a lack of contextual triage. 7-9,13 Our findings demonstrate that an LLM-equipped agent can synthesize clinical context to triage vital signs with high reliability, achieving high sensitivity for clinical deterioration while maintaining a manageable false-positive rate. While these retrospective results indicate that scalable, automated contextual triage is computationally feasible at $0.34 per reading, prospective clinical trials are required to determine whether this architecture reduces time-to-intervention or improves patient outcomes in active clinical environments. References 1. World Health Organization (WHO). Noncommunicable diseases. March 3, 2026, Accessed March 3, 2026, who.int/health-topics/noncommunicable-diseases 2. Buttorff C, Ruder T, Bauman M. Multiple chronic conditions in the United States. vol 10. Rand Santa Monica, CA; 2017. 3. National health expenditure data: historical (2024). 4. Centers for Medicare & Medicaid Services (CMS). Remote Patient Monitoring. March 3, 2026, Updated January 1, 2026. Accessed March 3, 2026, https://w.cms.gov/medicare/coverage/telehealth/remote-patient-monitoring 5. Joo JH, Lieu N, Tang Y, Browne DS, Agusala B, Liao JM. Trends in utilization of remote monitoring in the United States. Health Affairs Scholar. 2025;3(6):qxaf115. 6. Office of Inspector General (OIG). Additional Oversight of Remote Patient Monitoring in Medicare Is Needed. 2024. September 2024. https://oig.hhs.gov/documents/evaluation/10001/OEI-02-23- 00260.pdf 7. Chaudhry SI, Mattera JA, Curtis JP, et al. Telemonitoring in patients with heart failure. New England Journal of Medicine. 2010;363(24):2301â2309. 8. Ong MK, Romano PS, Edgington S, et al. Effectiveness of remote patient monitoring after discharge of hospitalized patients with heart failure: the better effectiveness after transitionâheart failure (BEAT-HF) randomized clinical trial. JAMA internal medicine. 2016;176(3):310â318. 9. Koehler F, Winkler S, Schieber M, et al. Impact of remote telemedical management on mortality and hospitalizations in ambulatory patients with chronic heart failure: the telemedical interventional monitoring in heart failure study. Circulation. 2011;123(17):1873â1880. 10. Koehler F, Winkler S, Schieber M, et al. Telemedicine in heart failure: pre-specified and exploratory subgroup analyses from the TIM-HF trial. International journal of cardiology. 2012;161(3):143â150. 11. Nakamura N, Koga T, Iseki H. A meta-analysis of remote patient monitoring for chronic heart failure patients. Journal of telemedicine and telecare. 2014;20(1):11â17. 12. Scholte NT, GĂŒrgöze MT, Aydin D, et al. Telemonitoring for heart failure: a meta-analysis. European heart journal. 2023;44(31):2911â2926. 13. Stevenson LW, Ross HJ, Rathman LD, Boehmer JP. Remote monitoring for heart failure management at home: JACC scientific statement. Journal of the American College of Cardiology. 2023;81(23):2272â2291. 14. Siebig S, Kuhls S, Imhoff M, Gather U, Schölmerich J, Wrede CE. Intensive care unit alarmsâ how many do we need? Critical care medicine. 2010;38(2):451â456. 15. Lee NS, Anastos-Wallen R, Chaiyachati KH, Reitz C, Asch DA, Mehta SJ. Clinician decisions after notification of elevated blood pressure measurements from patients in a remote monitoring program. JAMA Network Open. 2022;5(1):e2143590. 16. Samal L, Chen SW, Lipsitz S, et al. User actions within a clinical decision support alert for the management of hypertension in chronic kidney disease. Applied Clinical Informatics. 2025;16(03):595â 603. 17. The Joint Commission. Sentinel Event Alert. 2013. April 8, 2013. https://w.kff.org/wp- content/uploads/sites/2/2013/04/sea_50_alarms_4_5_13_final1.pdf 18. Koehler F, Koehler K, Deckwart O, et al. Efficacy of telemedical interventional management in patients with heart failure (TIM-HF2): a randomised, controlled, parallel-group, unmasked trial. The Lancet. 2018;392(10152):1047â1057. 19. Koehler F, Koehler K, Prescher S, et al. Mortality and morbidity 1 year after stopping a remote patient management intervention: extended follow-up results from the telemedical interventional management in patients with heart failure I (TIM-HF2) randomised trial. The Lancet Digital Health. 2020;2(1):e16âe24. 20. Prescher S, Winkler S, Riehle L, et al. Patient reported experience and adherence to remote patient management in chronic heart failure patients: a posthoc analysis of the TIM-HF2 trial. European Journal of Cardiovascular Nursing. 2023;22(3):245â253. 21. Singhal K, Azizi S, Tu T, et al. Large language models encode clinical knowledge. Nature. 2023;620(7972):172â180. 22. Singhal K, Tu T, Gottweis J, et al. Toward expert-level medical question answering with large language models. Nature medicine. 2025;31(3):943â950. 23. Nori H, King N, McKinney SM, Carignan D, Horvitz E. Capabilities of gpt-4 on medical challenge problems. arXiv preprint arXiv:230313375. 2023; 24. Tu T, Palepu A, Schaekermann M, et al. Towards conversational diagnostic AI. arXiv preprint arXiv:240105654. 2024; 25. Anthropic. Introducing the Model Context Protocol. Updated November 25, 2024. Accessed February 27, 2026, https://w.anthropic.com/news/model-context-protocol 26. Shaik T, Tao X, Higgins N, et al. Remote patient monitoring using artificial intelligence: Current state, applications, and challenges. Wiley Interdisciplinary Reviews: Data Mining and Knowledge Discovery. 2023;13(2):e1485. 27. Un K-C, Wong C-K, Lau Y-M, et al. Observational study on wearable biosensors and machine learning-based remote monitoring of COVID-19 patients. Scientific reports. 2021;11(1):4388. 28. Biofourmis. Accessed February 27, 2026, https://biofourmis.com/ 29. Health Recovery Solutions. Overcoming Healthcare Workforce Shortages through Remote Patient Monitoring and Clinical Support. March 3, 2026, Accessed February 27, 2026, https://w.healthrecoverysolutions.com/blog/overcoming-healthcare-workforce-shortages-with-remote- monitoring 30. KLAS Research. Best in KLAS 2023: Remote Patient Monitoring. March 3, 2026, Updated March 3, 2026. Accessed March 3, 2026, https://klasresearch.com/best-in-klas-ranking/remote-patient- monitoring/2023/338 31. Masimo. Accessed February 27, 2026, https://w.masimo.com/products/remote- monitoring/safetynet/ 32. Haim GB, Saban M, Barash Y, et al. Evaluating Large Language ModelâAssisted Emergency Triage: A Comparison of Acuity Assessments by GPTâ4 and Medical Experts. Journal of clinical nursing. 2024; 33. Williams CY, Zack T, Miao BY, et al. Use of a large language model to assess clinical acuity of adults in the emergency department. JAMA network open. 2024;7(5):e248895. 34. Shashikumar SP, Mohammadi S, Krishnamoorthy R, et al. Development and prospective implementation of a large language model based system for early sepsis prediction. npj Digital Medicine. 2025;8(1):290. 35. Ferber D, El Nahhas OS, Wölflein G, et al. Development and validation of an autonomous artificial intelligence agent for clinical decision-making in oncology. Nature cancer. 2025;6(8):1337â 1349. 36. Jiang Y, Black KC, Geng G, et al. MedAgentBench: a virtual EHR environment to benchmark medical LLM agents. Nejm Ai. 2025;2(9):AIdbp2500144. 37. Schmidgall S, Ziaei R, Harris C, Reis E, Jopling J, Moor M. Agentclinic: a multimodal agent benchmark to evaluate ai in simulated clinical environments. arXiv preprint arXiv:240507960. 2024; 38. Siwicki B. How health systems can prepare for the next phase of AI adoption. Healthcare IT News. December 26, 2025. https://w.healthcareitnews.com/news/how-health-systems-can-prepare- next-phase-ai-adoption 39. Schmiedmayer P, Rao A, Zagar P, et al. LLMonFHIR: A Physician-Validated, Large Language ModelâBased Mobile Application for Querying Patient Electronic Health Data. JACC: Advances. 2025;4(6_Part_1):101780. 40. Kim Y, Park C, Jeong H, et al. Mdagents: An adaptive collaboration of llms for medical decision- making. Advances in Neural Information Processing Systems. 2024;37:79410â79452. 41. Mukherjee S, Gamble P, Ausin MS, et al. Polaris: A safety-focused llm constellation architecture for healthcare. arXiv preprint arXiv:240313313. 2024; 42. Anthropic. System Card: Claude Opus 4.6. 2026. February 2026. https://w- cdn.anthropic.com/c788cbc0a3da9135112f97cdf6dcd06f2c16cee2.pdf 43. Jones DW, Ferdinand KC, Taler SJ, et al. 2025 AHA/ACC/AANP/AAPA/ABC/ACCP/ACPM/AGS/AMA/ASPC/NMA/PCNA/SGIM guideline for the prevention, detection, evaluation and management of high blood pressure in adults: a report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines. Circulation. 2025;152(11):e114âe218. 44. Cuba Gyllensten I, Bonomi AG, Goode KM, et al. Early indication of decompensated heart failure in patients on home-telemonitoring: a comparison of prediction algorithms based on daily weight and noninvasive transthoracic bio-impedance. JMIR medical informatics. 2016;4(1):e3. 45. Roubille F, Mercier G, Lancman G, et al. Weight telemonitoring of heart failure versus standard of care in a real-world setting: Results on mortality and hospitalizations in a 6-month nationwide matched cohort study. European Journal of Heart Failure. 2024;26(5):1201â1214. 46. National Early Warning Score (NEWS) 2: Standardising the assessment of acute-illness severity in the NHS (2017). 47. Landis JR, Koch G. The measurement of observer agreement for categorical data. Biometrics. 1977:159â174. 48. ADVOCATE: Agentic AI-Enabled Cardiovascular Care Transformation (2026). 49. Clinical Decision Support Software: Guidance for Industry and Food and Drug Administration Staff (2026). 50. MeskĂł B, Topol EJ. The imperative for regulatory oversight of large language models (or generative AI) in healthcare. NPJ digital medicine. 2023;6(1):120. Tables Referenced in Text Table 1: Study Population Demographics (Section 3.1) Table 2: MCP Tool Inventory (Section 3.2.1) Table 3: Agent Self-Agreement: Fleissâ Kappa (Section 4.1) Table 4: Alert Rate Comparison: Fixed Threshold vs. Adaptive vs. Agent (Section 4.2) Table 5: Intra-Rater Reliability (Section 4.3.1) Table 6: Inter-Reviewer Agreement Distribution (Section 4.3.2) Table 7: Reviewer-Agent Pairwise Agreement (Section 4.3.3) Table 8: Agent Performance vs. Majority Vote Reference Standard (Section 4.4) Table 9: Agent Per-Category Performance vs. Majority-Vote Reference Standard (Section 4.4) Table 10: Binary Classification Performance: Actionable vs. Non-Actionable (Section 4.4) Table 11. Head-to-Head Performance: Agent vs. Rule-Based Baselines Against Majority-Vote Reference Standard (Section 4.4.1) Table 12: Leave-One-Out Analysis: Individual Clinician vs. Agent Performance (Section 4.5) Table 13: Human Expert Adjudication of Severe Agent Overtriage Cases (Section 4.6) Table 14: Operational Metrics by Study (Section 4.7) Table 15: Duration of Triage: Agent vs. Human Reviewers (Section 4.8) Figures Referenced in Text Figure 1: Sentinel System Architecture (Section 3.2) Figure 2: Severity Classification Decision Guidelines (Section 3.2) Figure 3: Inter-Reviewer Pairwise Exact Agreement Matrix (Section 4.3.2) Figure 4: Agent vs. Human Majority Vote Confusion Matrix (Section 4.4) Figure 5. Leave-One-Out Analysis: Individual Clinician vs. Agent Performance (Section 4.5) Figure 6: Tool Usage Gradient by Alert Severity (Section 4.7) Figure 7: Case Example A (Section 4.9.1) Figure 8: Case Example B (Section 4.9.1) Figure 9: Case Example C (Section 4.9.1) Figure 10: Case Example D (Section 4.9.2) Figure 11: Case Example E (Section 4.9.2) Author Contributions M.J.P. conceived the study, designed the system architecture, and wrote the manuscript. S.K. performed data analysis and wrote the manuscript. S.K., H.V., and K.S. contributed to system development. D.E. managed data infrastructure. J.A., D.S., A.L.D., A.C., W.B., and T.K. served as clinician reviewers. The initial manuscript drafting was assisted by an LLM (Claude, Anthropic), with comprehensive author review and revision. All authors reviewed and approved the final manuscript. Conflicts of Interest M.J.P. is the founder and CEO of AnsibleHealth Inc. This study was conducted using AnsibleHealthâs deployed clinical systems and patient data. All other authors have declared no competing interests. Data Availability The study data and the Sentinel system architecture is proprietary. MCP tool interfaces are described in sufficient detail for replication. Ethics This study was conducted as a quality improvement initiative within AnsibleHealthâs polychronic medical home program. Patient data accessed by the AI agent were used within the existing scope of clinical care. This study was reviewed by the Advarra Institutional Review Board (IRB) and determined to be exempt from IRB oversight under Department of Health and Human Services regulations (45 CFR 46.104(d)(4)). Furthermore, to ensure patient safety during the data evaluation, a built-in clinical safety net was utilized: any vital sign measurements classified as âurgentâ or âemergencyâ by any reviewing clinician were immediately escalated to the active AnsibleHealth clinical team for medical evaluation and appropriate patient follow-up. Funding This work was self-funded by AnsibleHealth Inc. No external funding was received. Acknowledgments The authors thank the AnsibleHealth clinical team for their contributions to system development and clinical review, and the patients whose data enabled this research. Appendix Appendix Table A1. Fixed Threshold Baseline vs. Majority-Vote Reference Standard Confusion Matrix (N=467) Fixed \ Human Majority Emergency Urgent Monitor Not an Issue Total EMERGENCY 0 0 0 0 0 URGENT 24 78 96 52 250 MONITOR 0 2 17 35 54 NOT AN ISSUE 0 0 8 155 163 Total 24 80 121 242 467 Note: The fixed threshold baseline produced no EMERGENCY classifications. All 24 true EMERGENCY cases were classified as URGENT (the baselineâs highest effective severity level for these readings). The systemâs high sensitivity (96.4%) was driven by aggressive alerting: 250/467 readings (53.5%) were classified URGENT, of which 172 (68.8%) were overtriaged relative to the majority-vote reference standard. Appendix Table A2. Adaptive Baseline vs. Majority-Vote Reference Standard Confusion Matrix (N=467) Adaptive \ Human Majority Emergency Urgent Monitor Not an Issue Total EMERGENCY 2 6 6 0 14 URGENT 4 7 10 6 27 MONITOR 7 10 14 25 56 NOT AN ISSUE 11 57 91 211 370 Total 24 80 121 242 467 Note: The adaptive baseline classified 79.2% of readings (370/467) as NOT AN ISSUE, reflecting its reliance on patient-specific rolling statistics that treated chronically abnormal values as within-range. Among the 225 clinician-identified alerts, 159 (70.7%) were missed entirely. The systemâs near-chance four-level accuracy (50.1%) reflected poor discrimination across all severity levels. Appendix Table A3. Agent Configuration Parameter Value Model Claude Opus 4.6 (claude-opus-4-6) Maximum agentic turns 15 Wall-clock timeout 120 seconds Temperature 1.0 (Anthropic default; no override) Top-p Not set (Anthropic default) Permission mode acceptEdits (all tool calls auto-approved) MCP servers 3 (patient clinical data, SNOMED-CT terminology, ICD-10 terminology) Appendix Table A4. Per-Clinician Agent Leave-One-Out Analysis Reviewer LOO Samples Exact Match Emergency Sensitivity Actionable Sensitivity MD1 154 78.6% 9/9 (100%) 27/30 (90.0%) MD2 135 71.9% 6/6 (100%) 19/22 (86.4%) MD3 153 77.1% 5/5 (100%) 23/26 (88.5%) NP1 161 73.3% 5/6 (83.3%) 28/30 (93.3%) NP2 149 76.5% 8/8 (100%) 19/21 (90.5%) NP3 143 75.5% 6/6 (100%) 24/25 (96.0%) Supplementary Algorithm S1. Fixed Threshold Baseline Criteria 1. Clinical Guideline Thresholds BP (blood pressure cuff) Rule Condition bp_crisis Systolic > 180 or diastolic > 120 hypotension Systolic < 90 or diastolic < 60 bpelevated140 Systolic > 140 bplow100 Systolic < 100 bp_range Systolic outside [90, 180] bpsinglecrisis Systolic >= 180 or diastolic >= 110 bpdrop20 Systolic drops >= 20 from previous reading bp_persistence >= 3 of last 10 readings with systolic > 140 or diastolic > 90 SpO2 (pulse oximeter) Rule Condition spo2copd88 SpO2 < 88% (COPD patients) spo2noncopd_94 SpO2 < 94% (non-COPD patients) Weight (bodyweight scale) HF patients only: Rule Condition hfweightgain0.9kg1d > 0.9 kg gain in 1 day hfweightgain5lbweek > 2.27 kg gain in 1 week hfsadelta0.9kg_1d >= 0.9 kg in 1 day (HFSA/ESC) hfsadelta2kg_3d >= 2 kg in 3 days cccweight3kg_2d >= 3 kg in 2 days cccweight2kg_5d >= 2 kg in 5 days All patients: Rule Condition multiweight1kg_1d > 1 kg gain in 1 day multiweight2kg_2d > 2 kg gain in 2 days multiweightloss3kg1d > 3 kg loss in 1 day multiweight2kg_baseline > 2 kg from 30-day median multiweight0.91kg_1wk > 0.91 kg gain in 1 week multiweight2.27kg_2wk > 2.27 kg gain in 2 weeks multiweight3.18kg_3wk > 3.18 kg gain in 3 weeks Criteria 2. Modified NEWS2 NEWS2 is a track-and-trigger early warning system (NHS/NICE) assigning 0â3 points to each vital sign. We adapted it to the subset of parameters collectable by home RPM devices: SpOâ (Scale 1 for non- COPD; Scale 2 for COPD/home Oâ), systolic blood pressure, and pulse rate. Because devices report asynchronously, scoring was performed at the individual reading level (BP readings: SBP + pulse rate; SpOâ readings: SpOâ + pulse). SpOâ Scoring (Scale 1): SpOâ (%) â€91 92â93 94â95 â„96 Score 3 2 1 0 Systolic BP Scoring: SBP (mmHg) â€90 91â100 101â110 111â219 â„220 Score 3 2 1 0 3 Pulse Rate Scoring: Pulse (bpm) â€40 41â50 51â90 91â110 111â130 â„131 Score 3 1 0 1 2 3 Aggregate Score and Clinical Escalation Flag Assignment: NEWS2 Trigger Flag Total score 0 NOT AN ISSUE Total score 1â4 MONITOR Score of 3 in any single parameter URGENT Total score 5â6 URGENT Total score â„7 EMERGENCY Final classification = MAX(Criteria 1, Criteria 2) Supplementary Algorithm S2. Adaptive Baseline Pseudocode The adaptive baseline classifier used patient-specific rolling statistics computed from a 30-day history window. Each sub-measurement within a device reading was evaluated independently (e.g., systolic, diastolic, and pulse rate for a blood pressure cuff reading), and the final classification was the maximum severity across all sub-measurements and all triggered rules. A minimum of 10 prior readings was required; readings with insufficient history were classified as NOT AN ISSUE. Three rule families were applied to each sub-measurement: Rule 1: Deviation from Rolling Mean (Ï-band classification) Input: current value v, 30-day history H Compute: ÎŒ = mean(H), Ï = SD(H) If |v â ÎŒ| > 4Ï â EMERGENCY Else if |v â ÎŒ| > 3Ï â URGENT Else if |v â ÎŒ| > 2Ï â MONITOR Else â NOT AN ISSUE Rule 2: Rate of Change (ÎŽ-band classification) Input: current value v, previous value v_prev, 30-day history of consecutive deltas Î Compute: current_ÎŽ = v â v_prev, Ï_Î = SD(Î) If |current_ÎŽ| > 4Ï_Î â EMERGENCY Else if |current_ÎŽ| > 3Ï_Î â URGENT Else if |current_ÎŽ| > 2Ï_Î â MONITOR Else â NOT AN ISSUE Rule 3: Persistence (consecutive readings outside Ï-bands) Input: last k readings (including current), same ÎŒ, Ï from Rule 1 Count consecutive readings (from most recent backward) outside each band If â„3 consecutive outside 4Ï â EMERGENCY Else if â„3 consecutive outside 3Ï â URGENT Else if â„3 consecutive outside 2Ï â MONITOR Else â NOT AN ISSUE Final classification = MAX severity across all sub-measurements Ă all three rules Sub-measurements evaluated per device type: Blood pressure cuff: systolic, diastolic, pulse_rate Pulse oximeter: SpO2, pulse Weight scale: bodyweight Pulse readings from both BP cuff (pulse_rate) and pulse oximeter (pulse) measured the same physiological parameter (heart rate) and were pooled across device types for history computation.