Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry
Madina Kojanazarova, Sidaty El Hadramy, Philippe C. Cattin
Intelligence
Status: succeeded | Model: Gemma-4-26B-A4B | Prompt: intel-v1 | Confidence: 92%
Last extracted: 8/24/2026, 5:48:18 AM
Summary
This paper presents a unified pipeline for generalizing soft tissue deformation and force prediction across varying material stiffnesses and geometries. The authors perform a comprehensive calibration of hyperelastic constitutive models (Ogden, Mooney-Rivlin, etc.) in the SOFA Framework using gravity-loaded silicone beams. Using the best-calibrated models to generate synthetic training data, they train a softness-conditioned equivariant graph neural network (GNN). The resulting surrogate model achieves sub-millimeter deformation accuracy and real-time inference (0.010s), demonstrating generalization across multiple tissue types and unseen geometries.
Entities (10)
Relation Signals (5)
Finite Element Method → generatesdatafor → Equivariant Graph Neural Network
confidence 95% · learning-based surrogate models trained on data using the finite element method (FEM)
Silicone Beams → usedforcalibration → Ogden Model
confidence 92% · We perform a comprehensive calibration of hyperelastic constitutive models... using gravity-loaded silicone beams
PyTorch Geometric → implements → Equivariant Graph Neural Network
confidence 90% · the GNN models were trained in PyTorch using the PyTorch Geometric (v2.8.0) package
Ogden Model → outperforms → Neo-Hookean Model
confidence 90% · Although the Ogden model was the slowest, it outperforms the other models in the S1 case
Equivariant Graph Neural Network → uses → SOFA Framework
confidence 85% · Using calibrated simulations [from SOFA] as training data, we use a softness conditioned equivariant graph neural network
Cypher Suggestions (0)
No Cypher suggestions yet.
Abstract
Abstract:Accurate soft tissue simulation is essential for surgical training, pre-operative planning, and haptic feedback systems. While learning-based surrogate models trained on data using the finite element method (FEM) offer a promising path to real-time inference, their reliability depends on well-calibrated constitutive models. Existing approaches neither provide systematic guidance on model selection across stiffness levels, nor generalize across different tissue stiffnesses or geometries. We perform a comprehensive calibration of hyperelastic constitutive models in the SOFA Framework using gravity-loaded silicone beams with different stiffnesses. Using calibrated simulations as training data, we use a softness conditioned equivariant graph neural network, enabling deformation and force prediction across multiple tissue types and unseen geometries. Our model achieves sub-millimeter mean deformation accuracy at 0.010s inference time, while showing that force prediction quality is directly tied to upstream calibration consistency.
Tags
Links
- Source: https://arxiv.org/abs/2608.20967v1
- Canonical: https://arxiv.org/abs/2608.20967v1
Trouble viewing inline? Open PDF directly →
Full Text
35,807 characters extracted from source content.
Expand or collapse full text
Generalizing Soft Tissue Deformation and Force Prediction Across Material Stiffness and Geometry Madina Kojanazarova Sidaty El Hadramy Philippe C. Cattin E-mail: M.Kojanazarova@unibas.ch Abstract Accurate soft tissue simulation is essential for surgical training, pre-operative planning, and haptic feedback systems. While learning-based surrogate models trained on data using the finite element method (FEM) offer a promising path to real-time inference, their reliability depends on well-calibrated constitutive models. Existing approaches neither provide systematic guidance on model selection across stiffness levels, nor generalize across different tissue stiffnesses or geometries. We perform a comprehensive calibration of hyperelastic constitutive models in the SOFA Framework using gravity-loaded silicone beams with different stiffnesses. Using calibrated simulations as training data, we use a softness conditioned equivariant graph neural network, enabling deformation and force prediction across multiple tissue types and unseen geometries. Our model achieves sub-millimeter mean deformation accuracy at 0.010 s0.010\,s inference time, while showing that force prediction quality is directly tied to upstream calibration consistency. Keywords: soft tissue simulation, finite element method, graph neural networks †tocauthor: Madina Kojanazarova, Sidaty El Hadramy, Philippe C. Cattin†institute: University of Basel, Department of Biomedical Engineering, Allschwil, Switzerland 1 Introduction Minimally invasive surgery and robotic-assisted interventions increasingly rely on accurate models of soft tissue behavior to support surgical training, pre-operative planning, and intraoperative guidance 4. A core challenge in all of these applications is predicting how tissue deforms under tool contact in real time: deformation fields are needed to update augmented reality overlays 10, and contact forces must be rendered haptically to give trainees realistic tactile feedback 17. Physics-based simulation using the finite element method (FEM) can reproduce soft tissue deformation with high fidelity by solving the equations of continuum mechanics on a volumetric mesh 21, but the computational cost of solving large nonlinear systems at each time step typically precludes real-time use, with simulation times orders of magnitude above the millisecond budgets required for interactive applications 18. A widely adopted strategy to overcome this bottleneck is to use FEM offline to generate large bodies of high-fidelity training data, and then train a fast surrogate model that approximates the FEM response at inference time 15; 5. Once trained, such surrogates can deliver predictions in milliseconds, enabling integration into real-time surgical simulators without sacrificing the physical realism of the underlying simulation. Among the available surrogate architectures, graph neural networks (GNNs) are particularly well-suited to this task. They operate natively on unstructured meshes and point clouds, naturally handle irregular and patient-specific geometries, and can propagate local deformation cues globally through message passing 19; 5. However, existing surrogates face key limitations. First, generalization across unseen geometries and varying material stiffness simultaneously remains an open challenge. Existing approaches typically fix one or both of these properties at training time 5; 7; 13; 12; 15. Second, any surrogate trained on FEM data is only as reliable as the underlying simulation. A critical and often overlooked prerequisite is the selection and calibration of the constitutive model 6; 14 and the mathematical description of how stress relates to strain in the tissue 3. Simulation frameworks such as the SOFA Framework 8, widely used in medical simulation research, provide several hyperelastic constitutive models, each encoding different assumptions about material microstructure. Yet there is no systematic guidance on which model best captures the behavior of silicone-like soft materials across different stiffness levels, and parameters overfit to a single configuration will directly corrupt the FEM training data and, by extension, the surrogate trained on it. In this work, we address these limitations in a unified pipeline, illustrated in Fig. 1. First, we fabricate silicone beams at three stiffness levels and use gravity-loading experiments across multiple lengths and boundary conditions as a controlled calibration benchmark (Section 3.1). We then systematically optimize the parameters of all applicable hyperelastic models in SOFA 8 and evaluate which models reproduce the physical deformation most accurately across stiffness levels (Section 3.2). Using the best-performing models and calibrated parameters, we generate a synthetic dataset of poking interactions on soft volumes with varied embedded geometries spanning all three stiffness levels (Section 3.3). Finally, this dataset is used to train a softness-conditioned extension of the equivariant GNN of 13, enabling a single network to predict deformation and contact force across multiple material classes and generalize to unseen geometries, bringing us closer to a fast, generalizable surrogate for real-time soft tissue simulation. Figure 1: Overview of the proposed pipeline for experimental material calibration, synthetic data generation, and surrogate learning. 2 Background 2.1 Physics-Based Soft Tissue Simulations Soft tissues exhibit hyperelastic behavior where, under large deformations, the stress-strain relationship is nonlinear. This behavior is commonly modeled in continuum mechanics as a strain energy density function Ψ , defined as a function of the deformation gradient F, its determinant J=detJ= (the local volume ratio), and the right Cauchy-Green tensor =TC=F^TF, whose invariants are I1=tr(),I2=12[(tr)2−tr(2)].I_1=tr(C), I_2= 12 [(tr\,C)^2-tr(C^2) ]. (1) Hyperelastic models differ in how Ψ is formulated, reflecting different assumptions about the underlying material microstructure and trade-offs between accuracy and numerical stability. Saint Venant-Kirchhoff The simplest of the models considered, extends the classical linear (Hookean) stress-strain relationship to large displacements by replacing the linear strain tensor with the nonlinear Green-Lagrange strain tensor =12(−)E= 12(C-I): ΨStVK=λ2tr()2+μtr(2), _StVK= λ2\,tr(E)^2+μ\,tr(E^2), (2) with λ and μ being the Lamé parameters. Because the stress remains a linear function of E, the model is computationally efficient but physically unrealistic at large compressive strains, where it can produce non-physical, non-monotonic stress responses 2. Neo-Hookean Derived from the statistical mechanics of polymer chains under the assumption of Gaussian chain-length statistics, the compressible Neo-Hookean model is given by: ΨNH=μ2(I1−3)−μlnJ+λ2(lnJ)2. _NH= μ2(I_1-3)-μ J+ λ2( J)^2. (3) With only two material parameters, it is the simplest true hyperelastic model and captures the qualitative nonlinearity of rubber-like materials, but it does not reproduce the pronounced strain-stiffening observed in real elastomers at large stretches 16. Stable Neo-Hookean A more recent reformulation of the Neo-Hookean model designed for robustness in simulation rather than fidelity to a specific microstructural derivation: ΨSNH=μ2(I1−3)−μ(J−1)+λ+μ2(J−1)2. _SNH= μ2(I_1-3)-μ(J-1)+ λ+μ2(J-1)^2. (4) By modifying the volumetric term relative to the standard compressible Neo-Hookean model, this formulation guarantees a positive semi-definite Hessian even under element inversion or extreme compression, eliminating the numerical instabilities that can otherwise arise during large or fast deformations 20. Mooney-Rivlin Proposed as a generalization of the Neo-Hookean model. The Mooney-Rivlin model introduces a second invariant term to better fit experimental stress-strain data over a wider strain range: ΨMR=C10(I¯1−3)+C01I¯2+K2(lnJ)2, _MR=C_10( I_1-3)+C_01 I_2+ K2( J)^2, (5) where I¯1 I_1, I¯2 I_2 are the volume-normalized invariants and K is the bulk modulus. The Neo-Hookean model is recovered as the special case when C01=0C_01=0 16. Ogden Rather than expressing Ψ in terms of invariants, the Ogden model is formulated directly in terms of the principal stretches λ1 _1, λ2 _2, λ3 _3: ΨOgden=∑p=1Nμpαp(λ1αp+λ2αp+λ3αp−3)+K2(lnJ)2. _Ogden= _p=1^N _p _p ( _1 _p+ _2 _p+ _3 _p-3 )+ K2( J)^2. (6) This formulation offers greater flexibility in fitting complex, large-strain stress-stretch behavior, but with the need for an eigen-decomposition of the deformation tensor at each step, increasing computational cost 11. Arruda-Boyce Motivated by a non-Gaussian statistical model of polymer chains arranged on an eight-chain unit cell, the Arruda-Boyce model captures the limiting chain extensibility responsible for strain-stiffening at large stretches: ΨAB=μ∑i=15Ciλm2i−2(I1i−3i)+K2(lnJ)2, _AB=μ _i=1^5 C_i _m^2i-2 (I_1^i-3^i )+ K2( J)^2, (7) where C1,…,C5C_1,…,C_5 are fixed coefficients and λm _m is the locking stretch, the stretch at which the polymer network becomes fully extended, and it captures strain-stiffening behavior that the Neo-Hookean and Mooney-Rivlin models cannot 1. 2.2 Graph Neural Network for Soft Tissue Simulation Graph neural networks propagate information through message-passing layers that update node coordinates and features based on local neighborhoods, making them well-suited for unstructured mesh and point cloud data 9. Equivariance to rotations and translations allows the network to generalize across orientations without explicit data augmentation 19. The conditional equivariant GNN of 13 builds on this principle, taking as input a surface point cloud 0∈ℝN×dx^0 ^N× d (N surface points in 3D), per-point tissue features ∈ℝN×dh ^N× d encoding subsurface material composition sampled at 128 depth intervals beneath each point, and condition vectors s,e∈ℝ3C_s,C_e ^3 representing the start and end coordinates of the applied force. Information is propagated through L equivariant message-passing layers, and predictions are produced by two dedicated branches: one regressing per-point displacements ∈ℝN×3u ^N× 3 and one estimating scalar contact force F, with the deformed point cloud recovered as ^=+ y=u+x^0. We adopt this architecture without modification; full details are given in 13. The sole adaptation concerns the tissue feature encoding h, described in Section 3.4. 3 Methods 3.1 Physical Setup Silicone beams of three different stiffnesses were fabricated by varying the softener concentration in the mixture. Each beam was cast using a two-part silicone rubber (Eurosil 4 A+BA+B, Schouten SynTec, the Netherlands) combined with an oil-based softener (Eurosil Softener, Schouten SynTec, the Netherlands), mixed in an A:B:S ratio by weight, with A:B fixed at 1:1 and S varied at 0, 0.5, and 1. Throughout this paper, each mixture is referred to by its softener ratio, e.g. S0S0, S0.5S0.5, and S1S1 (corresponding to A:B:S = 1:1:0, 1:1:0.5, and 1:1:1). The cylindrical molds were 3D-printed with a length of 200 m200\,m and a radius of 10 m10\,m. Due to minor silicone leakage during casting, the beams varied slightly in final length. To obtain consistent and comparable deflection measurements, each beam was tested at standardized lengths: 50 m50\,m and 100 m100\,m in a cantilevered configuration (clamped at one end, free at the other), and 150 m150\,m in a clamped-clamped (fixed-fixed) configuration. In each case, deformation was recorded after the beam had fully stabilized under gravity. The deformed profiles were captured using a smartphone camera with a checkerboard reference pattern included in each frame (Fig. 2). We used OpenCV to compute a homography correcting perspective distortion and establishing an image resolution of 0.086±0.006 m/pixel0.086± 0.006\,mm/pixel. The corrected images were imported into CAD software and scaled using both the reference grid and the known diameter of an undeformed beam, minimizing scaling inaccuracies and compensating for perspective error from camera-to-specimen distance variation. The outer contour of the deformed specimen was manually traced from the calibrated images, and a centerline corresponding to the neutral axis was generated from this contour using the CAD software’s centerline function. The known cross-sectional diameter was then swept along this centerline, constrained by the traced outer contour, to reconstruct the 3D deformed geometry, serving as the reference for parameter calibration. Figure 2: Silicone beams at different lengths for the softener ratio S0.5S0.5. Figure 3: Optimization results for the Ogden model for softness S0.5S0.5. 3.2 Biomechanical Model & Parameter Optimization For each silicone mixture, we simulated the gravity-induced deformation of a cylindrical mesh with 72577257 nodes. The beam was fixed in SOFA, setting the boundary condition at the ends of the beam to match the physical experiments (Section 3.1). We rigidly constrained all translational degrees of freedom of every mesh node within a finite-length region at each clamped end (rather than a single end cross-section), matching the finite grip length of a physical clamp; no rotation or sliding was permitted within the clamped regions. The 50 50\, and 100 m100\,m beams were clamped at one end only (cantilevered, free at the other), while the 150 m150\,m beam was clamped identically at both ends. The mass density was set to 1000 kg/m31000\,kg/m^3 for all beams as the density variation due to softener content was considered negligible. We performed a parameter search over all hyperelastic constitutive models available in SOFA that are applicable to incompressible or near-incompressible soft materials. Each SOFA simulation ran for up to 10 00010\,000 steps at a 0.001 s0.001\,s time step. The simulation was run until equilibrium, defined as the root-mean-square (RMS) nodal displacement, measured as the change in node position over consecutive 50-step windows, remaining below 1 m1\,m, averaged across three consecutive windows (150150 steps total). For each model and each softener ratio S, parameters were optimized by maximizing the average volumetric overlap error across all three beam lengths, measured using the Dice score between the simulated and ground-truth 3D surface meshes. Optimizing across lengths simultaneously ensures the recovered parameters are consistent across boundary conditions rather than tuned to a single configuration. The optimization results and metrics for each model and softness level are reported in Table 1. We observe that most models could replicate the beam behavior with Dice scores >0.90>0.90 for the S0S0 and S0.5S0.5 softnesses. Although the Ogden model was the slowest, it outperforms the other models in the S1S1 case and manages to reflect the softer tissue best. Based on these results, Ogden and Mooney-Rivlin were selected for data generation, as they achieved the most reliable fits across all three softness levels. Table 1: Hyperelastic constitutive model calibration results across three softness levels (S0S0, S0.5S0.5, S1S1), optimized by maximizing volumetric overlap (Dice) between simulated and ground-truth beam deformations. For each softness level, metrics are averaged over the three tested beam lengths (50 m50\,m, 100 m100\,m, and 150 m150\,m). Surface distance, 95th percentile Hausdorff distance (HD95), Dice score, volume difference, and simulation time are reported per softness level and as an average. Model Softness Surface dist↓ [m] HD95↓ [m] Dice↑ Vol. diff.↓ [%] Time↓ [s] Arruda- Boyce S0S0 1.6971.697 4.3334.333 0.9550.955 0.7320.732 125.70125.70 S0.5S0.5 1.7651.765 4.5214.521 0.9360.936 2.6062.606 83.0483.04 S1S1 10.28110.281 22.66122.661 0.5710.571 2.8022.802 92.3092.30 Average 4.5814.581 10.50510.505 0.8210.821 2.0472.047 100.35100.35 Mooney- Rivlin S0S0 1.7061.706 4.3524.352 0.9530.953 0.7310.731 66.0966.09 S0.5S0.5 1.7531.753 4.5024.502 0.9430.943 2.6052.605 42.1842.18 S1S1 2.0082.008 5.0745.074 0.8890.889 2.2742.274 41.6241.62 Average 1.8221.822 4.6434.643 0.9230.923 1.8701.870 49.9649.96 Neo-Hookean S0S0 1.6911.691 4.3304.330 0.9570.957 0.7350.735 47.2947.29 S0.5S0.5 1.8381.838 4.7924.792 0.9160.916 2.6172.617 34.0934.09 S1S1 1.9931.993 5.0325.032 0.8910.891 2.3022.302 26.8926.89 Average 1.8411.841 4.7184.718 0.9210.921 1.8851.885 36.0936.09 Stable Neo-Hookean S0S0 1.7181.718 4.3494.349 0.9510.951 0.7380.738 45.0645.06 S0.5S0.5 1.8421.842 4.7274.727 0.9140.914 2.6252.625 28.5028.50 S1S1 3.4743.474 9.6259.625 0.7280.728 2.2322.232 30.4030.40 Average 2.3452.345 6.2346.234 0.8680.868 1.865 34.6534.65 Ogden S0S0 1.7731.773 4.4204.420 0.9340.934 0.7100.710 245.48245.48 S0.5S0.5 1.6771.677 4.3804.380 0.9670.967 2.5832.583 220.20220.20 S1S1 1.8771.877 4.8224.822 0.9260.926 4.0684.068 153.31153.31 Average 1.776 4.541 0.942 2.4542.454 203.33203.33 St Venant- Kirchhoff S0S0 1.7001.700 4.3194.319 0.9520.952 0.9480.948 20.1220.12 S0.5S0.5 1.9941.994 5.0545.054 0.8720.872 3.5073.507 35.8935.89 S1S1 2.6312.631 6.6966.696 0.7390.739 3.6283.628 18.8218.82 Average 2.1082.108 5.3565.356 0.8540.854 2.6942.694 24.95 3.3 Data Generation Training data was generated using the two best-performing models from the parameter optimization study, Ogden and Mooney-Rivlin, applied across all three softness levels. We constructed a rectangular soft tissue volume of 100×100×32 m100×100×32\,m with an embedded rigid inclusion. Eleven distinct inclusion shapes were designed, comprising cubes, spheres and cylinders of varying sizes, randomly positioned at the base of the volume (Fig. 4). The inclusion surfaces and the bottom face together defined the rigid boundary, while the remaining volume was discretized into tetrahedral elements representing the soft tissue. For each shape, we sampled two sets of poking locations on the top surface: 2020 fixed locations shared across all three softness levels, enabling direct comparison of the tissue response to softness alone, and 2020 randomly sampled locations drawn independently per softness level to increase contact configuration diversity In both cases, the poking angle was drawn up to 45° from the surface normal, with a maximum penetration depth of 30 m30\,m. The mesh was locally refined around each poking site and poking was performed using a cylindrical rod with a radius of 2.5 m2.5\,m and length of 40 m40\,m. Mesh resolution was determined via a convergence study on a homogeneous volume without rigid inclusion, comparing output forces at a penetration depth of 10 m10\,m, chosen because not all models are guaranteed to reach the full 30 m30\,m across all softness levels. The resulting dataset meshes ranged from 13 29713\,297 to 17 73217\,732 nodes (mean 15 95415\,954 ± 12541254) and 58 33058\,330 to 86 13086\,130 elements (mean 75 79275\,792 ± 81168116) across all shapes and softness levels. Each poking simulation was prescribed over 2 s2\,s with a time step of 0.002 s0.002\,s. The recorded outputs at each time step were the positions of all surface nodes and the total reaction force at the boundary nodes. To remove near-static timesteps, frames were retained only when the surface displacement at the contact tip exceeded 1 m1\,m relative to the previous retained frame, yielding a dataset of 11×3×40=132011× 3× 40=1320 pokings, with 1430514305 snapshots in the Ogden dataset and 1367213672 snapshots in the Mooney-Rivlin dataset. The complete features of the generated dataset can be seen in Table 2. Figure 4: Examples of generated binary shapes of soft tissues with rigid inclusions. Table 2: Features of the simulated dataset. SimaxSim_max and FmaxF_max indicate the average maximum depth and force reached per poke. TipmeanTip_mean and FmeanF_mean indicates the average depth and force in each snapshot. Model Softness SimaxSim_max [m] FmaxF_max [N] TipmeanTip_mean [m] FmeanF_mean [N] Mooney- Rivlin S0S0 13.92±3.8813.92± 3.88 12.92±5.3212.92± 5.32 7.91±4.827.91± 4.82 4.80±4.594.80± 4.59 S0.5S0.5 13.78±4.1413.78± 4.14 6.19±2.696.19± 2.69 7.94±4.897.94± 4.89 2.33±2.302.33± 2.30 S1S1 13.46±4.2413.46± 4.24 3.87±2.433.87± 2.43 7.82±4.877.82± 4.87 1.42±1.541.42± 1.54 Ogden S0S0 16.32±6.5316.32± 6.53 29.71±25.3129.71± 25.31 9.88±6.549.88± 6.54 6.94±11.446.94± 11.44 S0.5S0.5 16.40±6.4116.40± 6.41 18.35±18.6718.35± 18.67 9.89±6.549.89± 6.54 3.94±7.473.94± 7.47 S1S1 11.20±4.8211.20± 4.82 2.34±1.982.34± 1.98 7.04±4.877.04± 4.87 1.01±1.191.01± 1.19 3.4 Training Details We sampled 32×3232× 32 surface points on a regular grid from the FEM simulations to use as the input point cloud. In the original work 13, the depth profiles h were assigned a binary label: 0 for soft tissue and 1 for bone, reflecting the binary nature of the tissue. Since our dataset spans three silicone mixtures with distinct stiffnesses, we assigned each material a continuous stiffness value s∈[0,1]s∈[0,1], where higher values indicate stiffer material. The rigid inclusions retain a value of 1.01.0, while each silicone formulation is assigned a value derived from its softener ratio S, normalized such that the stiffest silicone S0S0 maps to 0.80.8, S0.5S0.5 maps to 0.40.4 and the softest S1S1 maps to 0.00.0. We split the data into training:validation:test in the order of shapes in an 7:2:2 ratio with 5-fold cross-validation, and trained the two datasets (Ogden and Mooney-Rivlin) separately for comparison, both including all softnesses. The models were trained for 200200 epochs using the Adam optimizer with a learning rate initialized to 10−410^-4 and a batch size of 6464. The loss function was defined the same as in 13, minimizing the weighted Euclidean distance error ℒdL_d and MSE for the force predictions ℒfL_f. We report all deformation errors computed using the standard (unweighted) Euclidean distances. The FEM simulations were performed on an AMD Epyc 7742 64-core CPU, and the GNN models were trained in PyTorch using the PyTorch Geometric (v2.8.0) package and run on a single NVIDIA RTX 2080 GPU. Table 3: GNN prediction results for the different datasets and softness levels. Dataset Softness Force Absolute Error [N] Mean Euclidean Distance [m] Max Euclidean Distance [m] Mean Relative Tip Error [%] Mooney- Rivlin S0S0 0.537±1.0010.537± 1.001 0.097±0.1520.097± 0.152 1.205±0.8541.205± 0.854 2.3±2.52.3± 2.5 S0.5S0.5 0.310±0.5400.310± 0.540 0.097±0.1550.097± 0.155 1.228±0.9241.228± 0.924 2.1±2.32.1± 2.3 S1S1 0.258±0.6500.258± 0.650 0.092±0.1570.092± 0.157 1.268±0.9441.268± 0.944 2.2±2.62.2± 2.6 Average 0.337±0.7080.337± 0.708 0.095±0.1550.095± 0.155 1.239±0.9181.239± 0.918 2.2±2.42.2± 2.4 Ogden S0S0 2.269±6.3582.269± 6.358 0.127±0.2090.127± 0.209 1.496±1.0841.496± 1.084 2.5±2.62.5± 2.6 S0.5S0.5 1.407±5.1551.407± 5.155 0.132±0.2190.132± 0.219 1.517±1.1041.517± 1.104 2.4±2.52.4± 2.5 S1S1 0.222±0.7760.222± 0.776 0.079±0.1450.079± 0.145 1.237±1.0131.237± 1.013 2.1±2.72.1± 2.7 Average 1.253±4.7511.253± 4.751 0.114±0.1980.114± 0.198 1.427±1.0801.427± 1.080 2.3±2.62.3± 2.6 4 Results & Discussion Table 3 reports deformation and force prediction errors per softness level and per constitutive model used to generate the training data (Mooney-Rivlin and Ogden), alongside the total across all conditions. Deformation accuracy Mean Euclidean distances are low and consistent across all conditions, averaging 0.095±0.155 m0.095± 0.155\,m for Mooney-Rivlin and 0.114±0.198 m0.114± 0.198\,m for Ogden, both below the 0.156±0.298 m0.156± 0.298\,m reported in 13 for a single-material and shape model. This suggests that extending training to multiple softness levels, combined with the continuous stiffness encoding, does not degrade deformation accuracy relative to the single-material baseline. The lower errors are likely due to the increased diversity of training configurations and shapes. The mean relative tip error remains consistently around 2−2.52-2.5% across all conditions for both models, further confirming reliable deformation prediction across the stiffness range. Force prediction Force errors are more variable and show a clear dependence on both the constitutive model and softness level. For Mooney-Rivlin, force errors are low and consistent across softness levels (0.258 N0.258\,N to 0.537 N0.537\,N), compared to those reported in 13 (0.701±1.111 N0.701± 1.111\,N). For Ogden, force errors are substantially higher and more variable for the stiffer mixture (S0S0: 2.269±6.358 N2.269± 6.358\,N, before dropping sharply for the softest level (S1S1: 0.222±0.776 N0.222± 0.776\,N). This pattern directly reflects the characteristics of the training data: as seen in the data features in Table 2, the Ogden model produces large and highly variable forces for stiffer materials, particularly S0S0 and S0.5S0.5, where the simulation reaches greater penetration depths before stabilizing. The resulting high variance in training targets makes force regression harder, and more training examples or a stronger tissue stiffness encoding in the model would likely reduce these errors. This high variance also partly reflects the imperfect calibration fit for stiffer Ogden conditions: parameters that do not perfectly reproduce physical behavior produce inconsistent force outputs across similar configurations, which directly increases the difficulty of the regression task. Effect of constitutive model The Mooney-Rivlin dataset produces more consistent GNN predictions overall, which we attribute to its more uniform force distributions across softness levels rather than superior physical accuracy. The Mooney-Rivlin simulations reach shallower maximum depths on average (Table 2), which limits force variability and results in a more learnable dataset. Ogden, by contrast, sustains larger deformations and generates physically richer force profiles, particularly for stiffer tissues, but at the cost of higher variance that the current model struggles to fit. This distinction is practically important, as Mooney-Rivlin may be preferable when training data consistency is the priority, while Ogden may be more appropriate when the goal is to cover the full range of tissue responses, provided sufficient training data and a more expressive tissue encoding are available. In both cases, deformation accuracy remains comparable, suggesting that the GNN’s displacement prediction is robust to the choice of constitutive model, while force prediction is more sensitive to training data characteristics. Across both datasets, a single inference took 0.010±0.004 s0.010± 0.004\,s (100 Hz100\,Hz), providing close to real-time predictions required for interactive surgical simulations. Additionally, as demonstrated in 13, the underlying architecture generalizes across point cloud densities and structures, a property inherited by our extension without additional training. 5 Conclusions We presented a pipeline for generalizable soft tissue simulation combining systematic calibration of SOFA hyperelastic constitutive models with a softness-conditioned graph neural network surrogate. Our calibration study identified Ogden and Mooney-Rivlin as the most reliable models across tested stiffness levels, while revealing the limitations of current constitutive models for very compliant materials. Conditioning the GNN on material stiffness enabled accurate deformation and force across three trained material softness levels and unseen inclusion geometries, maintaining sub-millimeter mean deformation accuracy at close to real-time inference speeds. These findings support the use of carefully calibrated FEM simulations as a basis for fast, generalizable data-driven surrogates in surgical simulation. The close to real-time inference speed of 0.010 s0.010\,s demonstrates the practical viability of such surrogates for integration into interactive surgical training systems with haptic feedback. References Arruda and Boyce (1993) E. M. Arruda and M. C. Boyce A three-dimensional constitutive model for the large stretch behavior of rubber elastic materials. Journal of the Mechanics and Physics of Solids 41 (2), p. 389–412. External Links: ISSN 0022-5096, Document Cited by: §2.1. Barbič and James (2005) J. Barbič and D. L. James Real-time subspace integration for st. venant-kirchhoff deformable models. ACM Trans. Graph. 24 (3), p. 982–990. External Links: ISSN 0730-0301, Document Cited by: §2.1. Bertram (2021) A. Bertram Hyperelasticity. In Elasticity and Plasticity of Large Deformations, p. 211–232. Cited by: §1. Cotin et al. (1999) S. Cotin, H. Delingette, and N. Ayache Real-time elastic deformations of soft tissues for surgery simulation. IEEE Trans. Vis. Comput. Graph. 5 (1), p. 62–73. External Links: Document Cited by: §1. Deshpande et al. (2024) S. Deshpande, S. P.A. Bordas, and J. Lengiewicz MAgNET: a graph u-net architecture for mesh-based simulations. Engineering Applications of Artificial Intelligence 133, p. 108055. External Links: ISSN 0952-1976, Document Cited by: §1, §1. El Hadramy et al. (2026) S. El Hadramy, B. Acidi, N. Padoy, and S. Cotin Optimization in latent space for real-time intraoperative characterization of digital twins. Eng. with Comput. 42 (2). External Links: ISSN 0177-0667, Document Cited by: §1. El Hadramy et al. (2025) S. El Hadramy, N. Padoy, and S. Cotin HyperU-mesh: real-time deformation of soft-tissues across variable patient-specific parameters. In Computational Biomechanics for Medicine, Cham, p. 129–139. External Links: ISBN 978-3-031-94128-3, Document Cited by: §1. Faure et al. (2012) F. Faure, C. Duriez, H. Delingette, J. Allard, B. Gilles, S. Marchesseau, H. Talbot, H. Courtecuisse, G. Bousquet, I. Peterlik, and S. Cotin SOFA: A Multi-Model Framework for Interactive Physical Simulation. In Soft Tissue Biomechanical Modeling for Computer Assisted Surgery, Y. Payan (Ed.), Studies in Mechanobiology, Tissue Engineering and Biomaterials, Vol. 11, p. 283–321. External Links: Document Cited by: §1, §1. Hamilton (2020) W. L. Hamilton Graph representation learning. Synthesis Lectures on Artificial Intelligence and Machine Learning 14 (3), p. 1–159. Cited by: §2.2. Kenngott et al. (2014) H. G. Kenngott, M. Wagner, M. Gondan, F. Nickel, M. Nolden, A. Fetzer, J. Weitz, L. Fischer, S. Speidel, H. Meinzer, D. Böckler, M. W. Büchler, and B. P. Müller-Stich Real-time image guidance in laparoscopic liver surgery: first clinical experience with a guidance system based on intraoperative ct imaging. Surgical Endoscopy 28 (3), p. 933–940. External Links: Document, ISBN 1432-2218 Cited by: §1. Kim et al. (2012) B. Kim, S. B. Lee, J. Lee, S. Cho, H. Park, S. Yeom, and S. Park A comparison among neo-hookean model, mooney-rivlin model, and ogden model for chloroprene rubber. International Journal of Precision Engineering and Manufacturing 13, p. . External Links: Document Cited by: §2.1. Kojanazarova et al. (2025a) M. Kojanazarova, F. Bieder, R. Sandkühler, and P. C. Cattin Conditional graph neural network for predicting soft tissue deformation and forces. In Computational Biomechanics for Medicine, Cham, p. 62–73. External Links: ISBN 978-3-031-94128-3, Document Cited by: §1. Kojanazarova et al. (2025b) M. Kojanazarova, S. E. Hadramy, J. Wilkie, G. Rauter, and P. C. Cattin Soft tissue simulation and force estimation from heterogeneous structures using equivariant graph neural networks. Healthcare Technology Letters 12 (1), p. e70042. External Links: Document, https://ietresearch.onlinelibrary.wiley.com/doi/pdf/10.1049/htl2.70042 Cited by: §1, §1, §2.2, §3.4, §3.4, §4, §4, §4. Mazier et al. (2022) A. Mazier, A. Bilger, A. E. Forte, I. Peterlik, J. S. Hale, and S. P. A. Bordas Inverse deformation analysis: an experimental and numerical assessment using the fenics project. Engineering with Computers 38 (5), p. 4099–4113. External Links: Document, ISBN 1435-5663 Cited by: §1. Mendizabal et al. (2020) A. Mendizabal, P. Márquez-Neila, and S. Cotin Simulation of hyperelastic materials in real-time using deep learning. Med. Image Anal. 59, p. 101569 (en). External Links: Document Cited by: §1, §1. Mihai et al. (2015) L. A. Mihai, L. Chin, P. A. Janmey, and A. Goriely A comparison of hyperelastic constitutive models applicable to brain and fat tissues. Journal of The Royal Society Interface 12 (110), p. 20150486. External Links: ISSN 1742-5689, Document, https://royalsocietypublishing.org/rsif/article-pdf/doi/10.1098/rsif.2015.0486/458247/rsif.2015.0486.pdf Cited by: §2.1, §2.1. Nguyen et al. (2023) C. C. Nguyen, S. Wong, M. T. Thai, T. T. Hoang, P. T. Phan, J. Davies, L. Wu, D. Tsai, H. Phan, N. H. Lovell, and T. N. Do Advanced user interfaces for teleoperated surgical robotic systems. Advanced Sensor Research 2 (4), p. 2200036. External Links: Document, https://advanced.onlinelibrary.wiley.com/doi/pdf/10.1002/adsr.202200036 Cited by: §1. Nguyen et al. (2020) T. Nguyen, M. Ho Ba Tho, and T. Dao A systematic review of real-time medical simulations with soft-tissue deformation: computational approaches, interaction devices, system architectures, and clinical validations. Applied Bionics and Biomechanics 2020 (1), p. 5039329. External Links: Document Cited by: §1. Satorras et al. (2021) V. G. Satorras, E. Hoogeboom, and M. Welling E(n) equivariant graph neural networks. In Proceedings of the 38th International Conference on Machine Learning, M. Meila and T. Zhang (Eds.), Proceedings of Machine Learning Research, Vol. 139, p. 9323–9332. External Links: Document Cited by: §1, §2.2. Smith et al. (2018) B. Smith, F. D. Goes, and T. Kim Stable neo-hookean flesh simulation. ACM Trans. Graph. 37 (2). External Links: ISSN 0730-0301, Document Cited by: §2.1. Taylor et al. (2008) Z. A. Taylor, M. Cheng, and S. Ourselin High-speed nonlinear finite element analysis for surgical simulation using graphics processing units. IEEE Trans. Med. Imaging 27 (5), p. 650–663 (en). Cited by: §1.